{"title":"Room sensor surface-mounted CO2","description":"\u003cp\u003eOur AERASGARD® air quality sensors reliably measure the CO2 concentration in the air. Many devices also measure humidity, temperature and air quality (VOC). This allows the entire indoor climate to be effectively monitored and controlled. Get a direct overview of our product range.\u003c\/p\u003e","products":[{"product_id":"multifunktionaler-aufputzfuehler-fuer-temperatur-und-co2-gehalt-kalibrierfaehig-mit-aktivem-schaltendem-ausgang-aerasgard-atm-co2-sd-u-0-10v-1501-7112-1001-200","title":"AERASGARD® ATM-CO2-SD-U","description":"Maintenance-free surface-mounted room climate sensor AERASGARD® ATM - CO2 - SD with active output, automatic calibration (fixed setting), in an impact-resistant plastic housing with quick-locking screws, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm) and the temperature (-35...+80 °C). The transmitter converts the measured variables into a standard signal of 0-10 V. \u003cbr\u003e\u003cbr\u003eThe transmitter is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being.\u003cbr\u003e\u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. \u003cbr\u003e\u003cbr\u003eAir quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255355146571,"sku":"1501-7112-1001-200","price":343.83,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/ALQ-CO2-W__tyr2_maxi-mL_4c_edd936bd-891d-4a92-8431-bcf42fcb83c8.png?v=1769688405"},{"product_id":"raum-luftguetefuehler-aerasgard-rco2-modbus-modbus-rtu-1501-61b0-6001-200","title":"AERASGARD® RCO2-Modbus","description":"Multifunctional room climate sensor AERASGARD® RFTM-LQ-PS-CO2-Modbus (maximum expansion stage) with Modbus connection, in an attractive plastic housing with snap-on cover, lower part with 4-hole mounting, optionally with\/without display, type variant RFTM-CO2-Modbus optionally with\/without setpoint potentiometer. The room sensor is used to measure humidity (0...100 % RH), temperature (0...+50°C), air quality (VOC) (0...100 % ), particulate matter (PM) (0...1000 µg\/m3) and CO2 content (0...5000 ppm) and as a room control unit (% setpoint). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), particulate matter (PM) and carbon dioxide (CO2). The entire indoor climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The air quality is determined on the basis of a (VOC) mixed gas sensor. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical fine dust sensor precisely detects particles (PM) in the size category 0.3 to 10 micrometres.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and two-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255374315851,"sku":"1501-61B0-6001-200","price":300.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Baldur2_maxi-mL_4c.png?v=1769689404"},{"product_id":"raum-luftguetefuehler-aerasgard-rco2-modbus-lcd-modbus-rtu-display-1501-61b0-6021-200","title":"AERASGARD® RCO2-Modbus LCD","description":"Multifunctional room climate sensor AERASGARD® RFTM-LQ-PS-CO2-Modbus (maximum expansion stage) with Modbus connection, in an attractive plastic housing with snap-on cover, lower part with 4-hole mounting, optionally with\/without display, type variant RFTM-CO2-Modbus optionally with\/without setpoint potentiometer. The room sensor is used to measure humidity (0...100 % RH), temperature (0...+50°C), air quality (VOC) (0...100 % ), particulate matter (PM) (0...1000 µg\/m3) and CO2 content (0...5000 ppm) and as a room control unit (% setpoint). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), particulate matter (PM) and carbon dioxide (CO2). The entire indoor climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The air quality is determined on the basis of a (VOC) mixed gas sensor. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical fine dust sensor precisely detects particles (PM) in the size category 0.3 to 10 micrometres.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and two-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255375003979,"sku":"1501-61B0-6021-200","price":355.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFTM-LQ-CO2-Modbus-Display__baldur2_maxi-mL_4c.png?v=1769689191"},{"product_id":"raum-co2-sensor-co2-fuehler-aerasgard-rco2-sd-u-0-10v-ohne-wechsler-1501-61a0-1001-200","title":"AERASGARD® RCO2-SD-U","description":"Maintenance-free room climate sensor AERASGARD® RCO2 - SD with active output, automatic calibration (fixed setting), in an attractive plastic housing with snap-on lid, for determining the CO2 content of the air (0...2000 ppm). The transmitter converts the measured variables into a standard signal of 0-10 V.\u003cbr\u003e\u003cbr\u003eMaintenance-free room climate sensor AERASGARD® RCO2 - W with active\/switching output, automatic calibration (can be switched off), in an attractive plastic housing with snap-on lid, optionally with traffic light display (five colored LEDs), for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm). The transmitter converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e The sensor is used in schools, public buildings, offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255375364427,"sku":"1501-61A0-1001-200","price":231.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RLQ__baldur1_maxi-mL_4c_0a53a907-b5d8-482f-a3d1-f848b21436cc.png?v=1769688723"},{"product_id":"raum-co2-sensor-co2-fuehler-aerasgard-rco2-w-0-10v-4-20ma-1-wechsler-24-v-wechsler-1501-61a0-7301-200","title":"AERASGARD® RCO2-W","description":"Maintenance-free room climate sensor AERASGARD® RCO2 - SD with active output, automatic calibration (fixed setting), in an attractive plastic housing with snap-on lid, for determining the CO2 content of the air (0...2000 ppm). The transmitter converts the measured variables into a standard signal of 0-10 V.\u003cbr\u003e\u003cbr\u003eMaintenance-free room climate sensor AERASGARD® RCO2 - W with active\/switching output, automatic calibration (can be switched off), in an attractive plastic housing with snap-on lid, optionally with traffic light display (five colored LEDs), for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm). The transmitter converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e The sensor is used in schools, public buildings, offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255375724875,"sku":"1501-61A0-7301-200","price":274.11,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RLQ__baldur1_maxi-mL_4c_09b6c53d-01e6-464e-bfdd-627d6df1e827.png?v=1769688756"},{"product_id":"raum-co2-sensor-co2-fuehler-aerasgard-rco2-w-a-0-10v-4-20ma-1-wechsler-24-v-led-wechsler-led-ampel-1501-61a0-7331-200","title":"AERASGARD® RCO2-W-A","description":"Maintenance-free room climate sensor AERASGARD® RCO2 - SD with active output, automatic calibration (fixed setting), in an attractive plastic housing with snap-on lid, for determining the CO2 content of the air (0...2000 ppm). The transmitter converts the measured variables into a standard signal of 0-10 V.\u003cbr\u003e\u003cbr\u003eMaintenance-free room climate sensor AERASGARD® RCO2 - W with active\/switching output, automatic calibration (can be switched off), in an attractive plastic housing with snap-on lid, optionally with traffic light display (five colored LEDs), for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm). The transmitter converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e The sensor is used in schools, public buildings, offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255376052555,"sku":"1501-61A0-7331-200","price":322.14,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RLQ-A__baldur1_maxi-mL_4c.png?v=1769688785"},{"product_id":"raum-co2-sensor-co2-fuehler-aerasgard-rco2-w-lcd-0-10v-4-20ma-1-wechsler-24-v-display-wechsler-display-1501-61b0-7321-200","title":"AERASGARD® RCO2-W LCD","description":"Maintenance-free room climate sensor AERASGARD® RCO2 - SD with active output, automatic calibration (fixed setting), in an attractive plastic housing with snap-on lid, for determining the CO2 content of the air (0...2000 ppm). The transmitter converts the measured variables into a standard signal of 0-10 V.\u003cbr\u003e\u003cbr\u003eMaintenance-free room climate sensor AERASGARD® RCO2 - W with active\/switching output, automatic calibration (can be switched off), in an attractive plastic housing with snap-on lid, optionally with traffic light display (five colored LEDs), for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm). The transmitter converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e The sensor is used in schools, public buildings, offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255376445771,"sku":"1501-61B0-7321-200","price":329.09,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFTM-LQ-CO2-Display-ppm__baldur2_maxi-mL_4c.png?v=1769688817"},{"product_id":"schul-co2-sensor-co2-ampel-aerasgard-rco2-as-frei-ohne-led-ohne-netzteil-led-ampel-summer-1501-61a0-0686-230","title":"AERASGARD® RCO2-AS","description":"Maintenance-free CO2 measuring transducer as room climate sensor AERASGARD® RCO2-AS xx with traffic light display and acoustic signal, self-calibrating, in an attractive plastic housing, for determining the CO2 content of the room air (0...3000 ppm). The measuring transducer converts the measured variable into a standard signal, which is immediately displayed visually in five stages via colored LEDs (traffic light display).   In addition, a signal tone sounds when the warning levels are reached (can be switched off via DIP switch).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eAvailable as a desktop device RCO2-AS NT ST with micro USB power supply and stainless steel stand, as well as the device variants RCO2-AS NT (with plug-in power supply unit), RCO2-AS UPNT (with flush-mounted power supply unit) and RCO2-AS (without power supply unit) for wall mounting. The room sensor with CO2 traffic light is used in classrooms, training and conference rooms, offices, hotels, apartments, stores, etc. and is used for quick and easy evaluation of the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. We recommend 1 sensor per 30 m² of room area.  CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology).","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255376871755,"sku":"1501-61A0-0686-230","price":48.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RCO2-AS__baldur1_maxi-mL_4c.png?v=1762856726"},{"product_id":"schul-co2-sensor-co2-ampel-aerasgard-rco2-as-nt-st-frei-ohne-stecker-netzteil-standhalter-led-ampel-summer-1501-61a0-0686-231","title":"AERASGARD® RCO2-AS NT ST","description":"Maintenance-free CO2 measuring transducer as room climate sensor AERASGARD® RCO2-AS xx with traffic light display and acoustic signal, self-calibrating, in an attractive plastic housing, for determining the CO2 content of the room air (0...3000 ppm). The measuring transducer converts the measured variable into a standard signal, which is immediately displayed visually in five stages via colored LEDs (traffic light display).   In addition, a signal tone sounds when the warning levels are reached (can be switched off via DIP switch).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eAvailable as a desktop device RCO2-AS NT ST with micro-USB power supply and stainless steel stand, as well as the device variants RCO2-AS NT (with plug-in power supply), RCO2-AS UPNT (with flush-mounted power supply) and RCO2-AS (without power supply) for wall mounting. The room sensor with CO2 traffic light is used in classrooms, training and conference rooms, offices, hotels, apartments, stores, etc. and is used for quick and easy evaluation of the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. We recommend 1 sensor per 30 m² of room area.  CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology).","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255377264971,"sku":"1501-61A0-0686-231","price":51.42,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RCO2-AS-NT-ST__baldur1_maxi-mL_4c.png?v=1762856782"},{"product_id":"schul-co2-sensor-co2-ampel-aerasgard-rco2-as-nt-frei-ohne-led-stecker-netzteil-led-ampel-summer-1501-61a0-0686-232","title":"AERASGARD® RCO2-AS NT","description":"Maintenance-free CO2 measuring transducer as room climate sensor AERASGARD® RCO2-AS xx with traffic light display and acoustic signal, self-calibrating, in an attractive plastic housing, for determining the CO2 content of the room air (0...3000 ppm). The measuring transducer converts the measured variable into a standard signal, which is immediately displayed visually in five stages via colored LEDs (traffic light display).   In addition, a signal tone sounds when the warning levels are reached (can be switched off via DIP switch).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eAvailable as a desktop device RCO2-AS NT ST with micro-USB power supply and stainless steel stand, as well as the device variants RCO2-AS NT (with plug-in power supply), RCO2-AS UPNT (with flush-mounted power supply) and RCO2-AS (without power supply) for wall mounting. The room sensor with CO2 traffic light is used in classrooms, training and conference rooms, offices, hotels, apartments, stores, etc. and is used for quick and easy evaluation of the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. We recommend 1 sensor per 30 m² of room area.  CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology).","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255377461579,"sku":"1501-61A0-0686-232","price":50.35,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RCO2-AS-NT__baldur1_maxi-mL_4c.png?v=1762856753"},{"product_id":"schul-co2-sensor-co2-ampel-aerasgard-rco2-as-upnt-frei-ohne-led-unterputz-netzteil-led-ampel-summer-1501-61a0-0686-233","title":"AERASGARD® RCO2-AS UPNT","description":"Maintenance-free CO2 measuring transducer as room climate sensor AERASGARD® RCO2-AS xx with traffic light display and acoustic signal, self-calibrating, in an attractive plastic housing, for determining the CO2 content of the room air (0...3000 ppm). The measuring transducer converts the measured variable into a standard signal, which is immediately displayed visually in five stages via colored LEDs (traffic light display).   In addition, a signal tone sounds when the warning levels are reached (can be switched off via DIP switch).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eAvailable as a desktop device RCO2-AS NT ST with micro-USB power supply and stainless steel stand, as well as the device variants RCO2-AS NT (with plug-in power supply), RCO2-AS UPNT (with flush-mounted power supply) and RCO2-AS (without power supply) for wall mounting. The room sensor with CO2 traffic light is used in classrooms, training and conference rooms, offices, hotels, apartments, stores, etc. and is used for quick and easy evaluation of the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. We recommend 1 sensor per 30 m² of room area.  CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology).","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255377494347,"sku":"1501-61A0-0686-233","price":87.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RCO2-AS-UPNT__baldur1-NT_maxi-mL_4c.png?v=1762856809"},{"product_id":"raum-co2-sensor-co2-fuehler-aerasgard-rco2-w-va-0-10v-4-20ma-1-wechsler-24-v-wechsler-1501-61a0-7301-205","title":"AERASGARD® RCO2-W VA","description":"Maintenance-free room climate sensor AERASGARD® RCO2 - W VA with active\/switching output, automatic calibration (can be switched off), in a vandal-proof stainless steel housing, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable).\u003cbr\u003e\u003cbr\u003e The sensor is used in schools, public buildings, offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255377625419,"sku":"1501-61A0-7301-205","price":391.76,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/VA2-Edelstahl__maxi-mL_4c.png?v=1769688841"},{"product_id":"raumfuehler-fuer-feuchte-temperatur-und-co2-aerasgard-rftm-co2-modbus-modbus-rtu-ohne-potentiometer-1501-61b6-6001-200","title":"AERASGARD® RFTM-CO2-Modbus","description":"Multifunctional room climate sensor AERASGARD® RFTM-LQ-PS-CO2-Modbus (maximum expansion stage) with Modbus connection, in an attractive plastic housing with snap-on cover, lower part with 4-hole mounting, optionally with\/without display, type variant RFTM-CO2-Modbus optionally with\/without setpoint potentiometer. The room sensor is used to measure humidity (0...100 % RH), temperature (0...+50°C), air quality (VOC) (0...100 % ), particulate matter (PM) (0...1000 µg\/m3) and CO2 content (0...5000 ppm) and as a room control unit (% setpoint). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), particulate matter (PM) and carbon dioxide (CO2). The entire indoor climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The air quality is determined on the basis of a (VOC) mixed gas sensor. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical fine dust sensor precisely detects particles (PM) in the size category 0.3 to 10 micrometres.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and two-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255377658187,"sku":"1501-61B6-6001-200","price":354.91,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFF-RFTF__baldur2_maxi-mL_4c_700a16ec-c0a5-4a9f-ba19-e79b0da8b8dc.png?v=1762857375"},{"product_id":"raumfuehler-fuer-feuchte-temperatur-und-co2-aerasgard-rftm-co2-modbus-lcd-modbus-rtu-display-ohne-potentiometer-1501-61b6-6021-200","title":"AERASGARD® RFTM-CO2-Modbus LCD","description":"Multifunctional room climate sensor AERASGARD® RFTM-LQ-PS-CO2-Modbus (maximum expansion stage) with Modbus connection, in an attractive plastic housing with snap-on cover, lower part with 4-hole mounting, optionally with\/without display, type variant RFTM-CO2-Modbus optionally with\/without setpoint potentiometer. The room sensor is used to measure humidity (0...100 % RH), temperature (0...+50°C), air quality (VOC) (0...100 % ), particulate matter (PM) (0...1000 µg\/m3) and CO2 content (0...5000 ppm) and as a room control unit (% setpoint). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), particulate matter (PM) and carbon dioxide (CO2). The entire indoor climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The air quality is determined on the basis of a (VOC) mixed gas sensor. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical fine dust sensor precisely detects particles (PM) in the size category 0.3 to 10 micrometres.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and two-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255377789259,"sku":"1501-61B6-6021-200","price":409.63,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFTM-LQ-CO2-Modbus-Display__baldur2_maxi-mL_4c_8f38cd2b-57ac-4660-9e89-be1dd6015067.png?v=1762857402"},{"product_id":"raumfuehler-fuer-feuchte-temperatur-und-co2-aerasgard-rftm-co2-modbus-p-modbus-rtu-potentiometer-1501-61b6-6501-271","title":"AERASGARD® RFTM-CO2-Modbus P","description":"Multifunctional room climate sensor AERASGARD® RFTM-LQ-PS-CO2-Modbus (maximum expansion stage) with Modbus connection, in an attractive plastic housing with snap-on cover, lower part with 4-hole mounting, optionally with\/without display, type variant RFTM-CO2-Modbus optionally with\/without setpoint potentiometer. The room sensor is used to measure humidity (0...100 % RH), temperature (0...+50°C), air quality (VOC) (0...100 % ), particulate matter (PM) (0...1000 µg\/m3) and CO2 content (0...5000 ppm) and as a room control unit (% setpoint). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), particulate matter (PM) and carbon dioxide (CO2). The entire indoor climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The air quality is determined on the basis of a (VOC) mixed gas sensor. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical fine dust sensor precisely detects particles (PM) in the size category 0.3 to 10 micrometres.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and two-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255378084171,"sku":"1501-61B6-6501-271","price":392.76,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RTR-S-011__baldur2_maxi-mL_4c_ae6acdf7-094b-4a9b-a683-d11aea1bf433.png?v=1762857420"},{"product_id":"raumfuehler-fuer-feuchte-temperatur-und-co2-aerasgard-rftm-co2-modbus-p-lcd-modbus-rtu-display-potentiometer-1501-61b6-6521-271","title":"AERASGARD® RFTM-CO2-Modbus P LCD","description":"Multifunctional room climate sensor AERASGARD® RFTM-LQ-PS-CO2-Modbus (maximum expansion stage) with Modbus connection, in an attractive plastic housing with snap-on cover, lower part with 4-hole mounting, optionally with\/without display, type variant RFTM-CO2-Modbus optionally with\/without setpoint potentiometer. The room sensor is used to measure humidity (0...100 % RH), temperature (0...+50°C), air quality (VOC) (0...100 % ), particulate matter (PM) (0...1000 µg\/m3) and CO2 content (0...5000 ppm) and as a room control unit (% setpoint). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), particulate matter (PM) and carbon dioxide (CO2). The entire indoor climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The air quality is determined on the basis of a (VOC) mixed gas sensor. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical fine dust sensor precisely detects particles (PM) in the size category 0.3 to 10 micrometres.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and two-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255378379083,"sku":"1501-61B6-6521-271","price":447.73,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFTM-LQ-CO2-Modbus-P-Display__baldur2_maxi-mL_4c.png?v=1762857439"},{"product_id":"raumfuehler-fuer-feuchte-temperatur-luftguete-und-co2-aerasgard-rftm-co2-w-0-10v-4-20ma-1-wechsler-24-v-wechsler-1501-61b6-7301-200","title":"AERASGARD® RFTM-CO2-W","description":"Maintenance-free room climate sensor AERASGARD® RFTM - CO2 - W\/ RFTM - LQ - CO2 - W\/ RTM - CO2 - SD with active\/switching output, automatic calibration (can be switched off), in an attractive plastic housing with snap-on lid, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (0...+50°C) and the relative humidity (0...100 % RH). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eA long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255378706763,"sku":"1501-61B6-7301-200","price":386.94,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFF-RFTF__baldur2_maxi-mL_4c_c9252ed1-b118-4a24-a4bf-4680ecbeeef3.png?v=1762857467"},{"product_id":"raumfuehler-fuer-feuchte-temperatur-luftguete-und-co2-aerasgard-rftm-co2-w-lcd-0-10v-4-20ma-1-wechsler-24-v-display-wechsler-1501-61b6-7321-200","title":"AERASGARD® RFTM-CO2-W LCD","description":"Maintenance-free room climate sensor AERASGARD® RFTM - CO2 - W\/ RFTM - LQ - CO2 - W\/ RTM - CO2 - SD with active\/switching output, automatic calibration (can be switched off), in an attractive plastic housing with snap-on lid, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (0...+50°C) and the relative humidity (0...100 % RH). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eA long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255379132747,"sku":"1501-61B6-7321-200","price":429.17,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFTM-CO2-Display-ppm__baldur2_maxi-mL_4c.png?v=1762857495"},{"product_id":"raumfuehler-fuer-feuchte-temperatur-luftguete-und-co2-aerasgard-rftm-lq-co2-w-0-10v-4-20ma-1-wechsler-24-v-wechsler-1501-61b8-7301-500","title":"AERASGARD® RFTM-LQ-CO2-W","description":"Maintenance-free room climate sensor AERASGARD® RFTM - CO2 - W\/ RFTM - LQ - CO2 - W\/ RTM - CO2 - SD with active\/switching output, automatic calibration (can be switched off), in an attractive plastic housing with snap-on lid, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (0...+50°C) and the relative humidity (0...100 % RH). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eA long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255379427659,"sku":"1501-61B8-7301-500","price":454.23,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFF-RFTF__baldur2_maxi-mL_4c_7b0e10c8-06fe-4906-98c9-51c8de7e60e7.png?v=1762857754"},{"product_id":"raumfuehler-fuer-feuchte-temperatur-luftguete-und-co2-aerasgard-rftm-lq-co2-w-lcd-0-10v-4-20ma-1-wechsler-24-v-display-wechsler-display-1501-61b8-7321-500","title":"AERASGARD® RFTM-LQ-CO2-W LCD","description":"Maintenance-free room climate sensor AERASGARD® RFTM - CO2 - W\/ RFTM - LQ - CO2 - W\/ RTM - CO2 - SD with active\/switching output, automatic calibration (can be switched off), in an attractive plastic housing with snap-on lid, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (0...+50°C) and the relative humidity (0...100 % RH). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eA long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255380083019,"sku":"1501-61B8-7321-500","price":509.21,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFTM-LQ-CO2-Display-ppm__baldur2_maxi-mL_4c_b328ddd9-600c-4262-9cce-7006d2b8172f.png?v=1762857783"},{"product_id":"raumfuehler-fuer-feuchte-temperatur-luftguete-und-co2-aerasgard-rtm-co2-sd-u-0-10v-1501-61b2-1001-200","title":"AERASGARD® RTM-CO2-SD-U","description":"Maintenance-free room climate sensor AERASGARD® RFTM - CO2 - W\/ RFTM - LQ - CO2 - W\/ RTM - CO2 - SD with active\/switching output, automatic calibration (can be switched off), in an attractive plastic housing with snap-on lid, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (0...+50°C) and the relative humidity (0...100 % RH). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eA long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255380410699,"sku":"1501-61B2-1001-200","price":253.33,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFF-RFTF__baldur2_maxi-mL_4c_5ca256df-641a-4f88-9b40-29674532f3ab.png?v=1762858416"},{"product_id":"raumfuehler-fuer-feuchte-temperatur-und-co2-aerasgard-rftm-lq-co2-modbus-modbus-rtu-1501-61b8-6001-500","title":"AERASGARD® RFTM-LQ-CO2-Modbus","description":"Multifunctional room climate sensor AERASGARD® RFTM-LQ-PS-CO2-Modbus (maximum expansion stage) with Modbus connection, in an attractive plastic housing with snap-on cover, lower part with 4-hole mounting, optionally with\/without display, type variant RFTM-CO2-Modbus optionally with\/without setpoint potentiometer. The room sensor is used to measure humidity (0...100 % RH), temperature (0...+50°C), air quality (VOC) (0...100 % ), particulate matter (PM) (0...1000 µg\/m3) and CO2 content (0...5000 ppm) and as a room control unit (% setpoint). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), particulate matter (PM) and carbon dioxide (CO2). The entire indoor climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The air quality is determined on the basis of a (VOC) mixed gas sensor. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical fine dust sensor precisely detects particles (PM) in the size category 0.3 to 10 micrometres.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and two-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255380771147,"sku":"1501-61B8-6001-500","price":480.94,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFF-RFTF__baldur2_maxi-mL_4c_8b94d2be-6566-4f5a-ac1d-450d1c0f11f3.png?v=1762857698"},{"product_id":"raumfuehler-fuer-feuchte-temperatur-und-co2-aerasgard-rftm-lq-co2-modbus-lcd-modbus-rtu-display-1501-61b8-6021-500","title":"AERASGARD® RFTM-LQ-CO2-Modbus LCD","description":"Multifunctional room climate sensor AERASGARD® RFTM-LQ-PS-CO2-Modbus (maximum expansion stage) with Modbus connection, in an attractive plastic housing with snap-on cover, lower part with 4-hole mounting, optionally with\/without display, type variant RFTM-CO2-Modbus optionally with\/without setpoint potentiometer. The room sensor is used to measure humidity (0...100 % RH), temperature (0...+50°C), air quality (VOC) (0...100 % ), particulate matter (PM) (0...1000 µg\/m3) and CO2 content (0...5000 ppm) and as a room control unit (% setpoint). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), particulate matter (PM) and carbon dioxide (CO2). The entire indoor climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The air quality is determined on the basis of a (VOC) mixed gas sensor. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical fine dust sensor precisely detects particles (PM) in the size category 0.3 to 10 micrometres.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and two-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255381066059,"sku":"1501-61B8-6021-500","price":535.91,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFTM-LQ-CO2-Modbus-Display__baldur2_maxi-mL_4c_d399887b-9258-4b17-89dd-92120d360ad7.png?v=1762857725"},{"product_id":"raumfuehler-fuer-feuchte-temperatur-luftqualitaet-voc-feinstaub-pm-und-co2-aerasgard-rftm-ps-lq-co2-modbus-modbus-rtu-1501-2119-6001-500","title":"AERASGARD® RFTM-PS-LQ-CO2 Modbus","description":"Multifunctional room climate sensor AERASGARD® RFTM-LQ-PS-CO2-Modbus (maximum expansion stage) with Modbus connection, in an attractive plastic housing with snap-on cover, lower part with 4-hole mounting, optionally with\/without display, type variant RFTM-CO2-Modbus optionally with\/without setpoint potentiometer. The room sensor is used to measure humidity (0...100 % RH), temperature (0...+50°C), air quality (VOC) (0...100 % ), particulate matter (PM) (0...1000 µg\/m3) and CO2 content (0...5000 ppm) and as a room control unit (% setpoint). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), particulate matter (PM) and carbon dioxide (CO2). The entire indoor climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The air quality is determined on the basis of a (VOC) mixed gas sensor. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical fine dust sensor precisely detects particles (PM) in the size category 0.3 to 10 micrometres.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and two-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255381524811,"sku":"1501-2119-6001-500","price":621.32,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFF-RFTF__baldur2_maxi-mL_4c_6e300a67-1003-4ba9-93b1-50a9f588c950.png?v=1762857894"},{"product_id":"raumfuehler-fuer-feuchte-temperatur-luftqualitaet-voc-feinstaub-pm-und-co2-aerasgard-rftm-ps-lq-co2-modbus-lcd-modbus-rtu-display-display-1501-2119-6021-500","title":"AERASGARD® RFTM-PS-LQ-CO2 Modbus LCD","description":"Multifunctional room climate sensor AERASGARD® RFTM-LQ-PS-CO2-Modbus (maximum expansion stage) with Modbus connection, in an attractive plastic housing with snap-on cover, lower part with 4-hole mounting, optionally with\/without display, type variant RFTM-CO2-Modbus optionally with\/without setpoint potentiometer. The room sensor is used to measure humidity (0...100 % RH), temperature (0...+50°C), air quality (VOC) (0...100 % ), particulate matter (PM) (0...1000 µg\/m3) and CO2 content (0...5000 ppm) and as a room control unit (% setpoint). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), particulate matter (PM) and carbon dioxide (CO2). The entire indoor climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The air quality is determined on the basis of a (VOC) mixed gas sensor. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical fine dust sensor precisely detects particles (PM) in the size category 0.3 to 10 micrometres.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and two-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255381983563,"sku":"1501-2119-6021-500","price":676.29,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFTM-LQ-PS-CO2-Modbus-Display-index6__baldur2_maxi-mL_4c.png?v=1762857930"},{"product_id":"raumfuehler-fuer-feuchte-temperatur-feinstaub-pm-und-co2-aerasgard-rftm-ps-co2-w-0-10v-4-20ma-1-wechsler-24-v-wechsler-1501-2113-7301-000","title":"AERASGARD® RFTM-PS-CO2-W","description":"Maintenance-free, multifunctional room climate sensor AERASGARD® RFTM - PS - CO2 - W with active\/switching output, automatic calibration, in an attractive plastic housing with snap-on lid, lower part with 4-hole mounting, optionally with\/without display, for recording the measured variables humidity (0...100 % RH), temperature (0...+50°C), particulate matter (PM) (0...50 \/ 100 \/ 300 \/ 500 μg\/m³) and CO2 content (0...2000 \/ 5000 ppm). The measuring transducer converts the measured variable into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eThe entire room climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical particle sensor precisely detects fine dust (PM) in the size category 0.3 to 10 micrometers. The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255383163211,"sku":"1501-2113-7301-000","price":514.56,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFF-RFTF__baldur2_maxi-mL_4c_7c7ab10c-f2c1-4b04-8ef6-d6e7504342f0.png?v=1762857819"},{"product_id":"raumfuehler-fuer-feuchte-temperatur-feinstaub-pm-und-co2-aerasgard-rftm-ps-co2-w-lcd-0-10v-4-20ma-1-wechsler-24-v-display-wechsler-display-1501-2113-7321-000","title":"AERASGARD® RFTM-PS-CO2-W LCD","description":"Maintenance-free, multifunctional room climate sensor AERASGARD® RFTM - PS - CO2 - W with active\/switching output, automatic calibration, in an attractive plastic housing with snap-on lid, lower part with 4-hole mounting, optionally with\/without display, for recording the measured variables humidity (0...100 % RH), temperature (0...+50°C), particulate matter (PM) (0...50 \/ 100 \/ 300 \/ 500 μg\/m³) and CO2 content (0...2000 \/ 5000 ppm). The measuring transducer converts the measured variable into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eThe entire room climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical particle sensor precisely detects fine dust (PM) in the size category 0.3 to 10 micrometers. The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255384408395,"sku":"1501-2113-7321-000","price":569.56,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFTM-LQ-CO2-Display-ppm__baldur2_maxi-mL_4c_f9932bf7-c835-468f-9aa2-e500318ce9c6.png?v=1762857857"},{"product_id":"raum-luftguetefuehler-raum-co2-und-luftqualitaetsfuehler-aerasgard-rlq-co2-w-0-10v-4-20ma-1-wechsler-24-v-wechsler-1501-61b1-7301-500","title":"AERASGARD® RLQ-CO2-W","description":"Maintenance-free room climate sensor AERASGARD® RLQ - CO2 - W with active\/switching output, automatic calibration (can be switched off), in an attractive plastic housing with snap-on lid, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (0...+50°C) and the relative humidity (0...100 % r.H.). The transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eA long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255395582283,"sku":"1501-61B1-7301-500","price":414.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RLQ__baldur1_maxi-mL_4c_10ff43ff-6bc0-496f-ab3b-a85456ecb5d8.png?v=1769689508"},{"product_id":"raum-luftguetefuehler-raum-co2-und-luftqualitaetsfuehler-aerasgard-rlq-co2-w-lcd-0-10v-4-20ma-1-wechsler-24-v-display-wechsler-1501-61b1-7321-500","title":"AERASGARD® RLQ-CO2-W LCD","description":"Maintenance-free room climate sensor AERASGARD® RLQ - CO2 - W with active\/switching output, automatic calibration (can be switched off), in an attractive plastic housing with snap-on lid, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (0...+50°C) and the relative humidity (0...100 % r.H.). The transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eA long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255398400331,"sku":"1501-61B1-7321-500","price":469.19,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFTM-LQ-CO2-Display-ppm__baldur2_maxi-mL_4c_d51f850a-e134-4458-95c8-c151f14c8045.png?v=1769689569"},{"product_id":"raum-luftguetefuehler-raum-co2-und-luftqualitaetsfuehler-aerasgard-rlq-co2-modbus-modbus-rtu-1501-61b1-6001-500","title":"AERASGARD® RLQ-CO2-Modbus","description":"Multifunctional room climate sensor AERASGARD® RFTM-LQ-PS-CO2-Modbus (maximum expansion stage) with Modbus connection, in an attractive plastic housing with snap-on cover, lower part with 4-hole mounting, optionally with\/without display, type variant RFTM-CO2-Modbus optionally with\/without setpoint potentiometer. The room sensor is used to measure humidity (0...100 % RH), temperature (0...+50°C), air quality (VOC) (0...100 % ), particulate matter (PM) (0...1000 µg\/m3) and CO2 content (0...5000 ppm) and as a room control unit (% setpoint). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), particulate matter (PM) and carbon dioxide (CO2). The entire indoor climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The air quality is determined on the basis of a (VOC) mixed gas sensor. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical fine dust sensor precisely detects particles (PM) in the size category 0.3 to 10 micrometres.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and two-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.\u003cp\u003e\u003c\/p\u003e","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255398695243,"sku":"1501-61B1-6001-500","price":440.89,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFF-RFTF__baldur2_maxi-mL_4c_a51309d4-5c5e-46fd-a646-c9a6178874dd.png?v=1769689446"},{"product_id":"raum-luftguetefuehler-raum-co2-und-luftqualitaetsfuehler-aerasgard-rlq-co2-modbus-lcd-modbus-rtu-display-1501-61b1-6021-500","title":"AERASGARD® RLQ-CO2-Modbus LCD","description":"Multifunctional room climate sensor AERASGARD® RFTM-LQ-PS-CO2-Modbus (maximum expansion stage) with Modbus connection, in an attractive plastic housing with snap-on cover, lower part with 4-hole mounting, optionally with\/without display, type variant RFTM-CO2-Modbus optionally with\/without setpoint potentiometer. The room sensor is used to measure humidity (0...100 % RH), temperature (0...+50°C), air quality (VOC) (0...100 % ), particulate matter (PM) (0...1000 µg\/m3) and CO2 content (0...5000 ppm) and as a room control unit (% setpoint). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), particulate matter (PM) and carbon dioxide (CO2). The entire indoor climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The air quality is determined on the basis of a (VOC) mixed gas sensor. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical fine dust sensor precisely detects particles (PM) in the size category 0.3 to 10 micrometres.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and two-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.\u003cp\u003e\u003c\/p\u003e","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255399088459,"sku":"1501-61B1-6021-500","price":495.87,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFTM-LQ-CO2-Modbus-Display__baldur2_maxi-mL_4c_76dcc3b8-931a-4436-9eb0-b5be4cad4a41.png?v=1769689426"},{"product_id":"raum-luftqualitaetsfuehler-voc-bzw-messumformer-aerasgard-rlq-w-va-0-10v-4-20ma-1-wechsler-24-v-wechsler-1501-61c0-7301-505","title":"AERASGARD® RLQ-W VA","description":"Maintenance-free room climate sensor AERASGARD® RLQ - SD with active output, automatic calibration (fixed setting), in an attractive plastic housing with snap-on lid, for determining the air quality or air quality in three VOC sensitivity levels (low\/medium\/high). The measuring transducer converts the measured variables into a standard signal of 0-10 V. \u003cbr\u003e\u003cbr\u003eMaintenance-free room climate sensor AERASGARD® RLQ - W with active\/switching output, automatic calibration (can be switched off), in an attractive plastic housing with snap-on cover, optionally with traffic light display (five colored LEDs), for determining the air quality or air quality in three VOC sensitivity levels (low\/medium\/high). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003eThe air quality is measured using a VOC sensor (mixed gas sensor for volatile organic substances). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255399416139,"sku":"1501-61C0-7301-505","price":318.72,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/VA2-Edelstahl__maxi-mL_4c_dde752a3-2ced-4709-9617-f3f64003a8ce.png?v=1769689686"},{"product_id":"multifunktionaler-aufputzfuehler-fuer-temperatur-und-co2-gehalt-kalibrierfaehig-mit-aktivem-schaltendem-ausgang-aerasgard-atm-co2-sd-u-1501-7112-1001-600","title":"AERASGARD® ATM-CO2-SD-U","description":"Maintenance-free surface-mounted room climate sensor AERASGARD® ATM - CO2 - SD with active output, automatic calibration (fixed setting), in an impact-resistant plastic housing with quick-locking screws, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm) and the temperature (-35...+80 °C). The transmitter converts the measured variables into a standard signal of 0-10 V. \u003cbr\u003e\u003cbr\u003eThe transmitter is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being.\u003cbr\u003e\u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. \u003cbr\u003e\u003cbr\u003eAir quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":56059370111307,"sku":"1501-7112-1001-600","price":343.83,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/ALQ-CO2-W__tyr2_maxi-mL_4c_f9d5a58f-f5a7-4a2f-83c4-5d10e8842e2c.png?v=1769688436"},{"product_id":"rftm-lq-co2-w","title":"RFTM-LQ-CO2-W","description":"","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":56992730710347,"sku":"1501-61B8-7301-600","price":454.23,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFF-RFTF__baldur2_maxi-mL_4c_dcef1440-192a-492d-a551-ca9a5619cd5b.png?v=1778044784"},{"product_id":"rftm-lq-co2-w-lcd","title":"RFTM-LQ-CO2-W LCD","description":"","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":57026898395467,"sku":"1501-61B8-7321-600","price":509.21,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Picture-not-available_d60ffe4b-a83b-4a36-8d02-64fbd4167d65.jpg?v=1776489680"},{"product_id":"rlq-co2-w-lcd","title":"RLQ-CO2-W LCD","description":"","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":57038730756427,"sku":"1501-61B1-7321-600","price":469.19,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Picture-not-available_efbf93ff-0520-431a-bc6e-e4c22224c546.jpg?v=1776489697"},{"product_id":"rftm-lq-co2-modbus","title":"RFTM-LQ-CO2-Modbus","description":"","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":57047466115403,"sku":"1501-61B8-6001-600","price":480.94,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Picture-not-available_4d24175b-3f81-4908-8f90-7e0d30c02a4a.jpg?v=1776489677"},{"product_id":"rftm-lq-co2-modbus-lcd","title":"RFTM-LQ-CO2-Modbus LCD","description":"","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":57047466541387,"sku":"1501-61B8-6021-600","price":535.91,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Picture-not-available_4c657f18-24cc-4e9d-8d4b-90367447003d.jpg?v=1776489677"},{"product_id":"rftm-ps-lq-co2-modbus-lcd","title":"RFTM-PS-LQ-CO2 Modbus LCD","description":"","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":57047466639691,"sku":"1501-2119-6021-600","price":676.29,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Picture-not-available_18d36c2e-0190-4caf-8ed9-5c445780534e.jpg?v=1776489687"},{"product_id":"rlq-co2-modbus","title":"RLQ-CO2-Modbus","description":"","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":57047467065675,"sku":"1501-61B1-6001-600","price":440.89,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Picture-not-available_e388f3e7-6937-4c82-a206-2198f6d44d51.jpg?v=1776489690"},{"product_id":"rlq-co2-modbus-lcd","title":"RLQ-CO2-Modbus LCD","description":"","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":57047467491659,"sku":"1501-61B1-6021-600","price":495.87,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Picture-not-available_946874b3-ccd1-4480-bba1-d04355943058.jpg?v=1776489690"},{"product_id":"rlq-co2-w","title":"RLQ-CO2-W","description":"","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":57236457947467,"sku":"1501-61B1-7301-600","price":414.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RLQ__baldur1_maxi-mL_4c_f03f5b2b-a955-402d-8793-1e00eaf1f87a.png?v=1778131613"}],"url":"https:\/\/www.spluss.com\/en-eu\/collections\/on-wall-co2-room-sensor.oembed","provider":"S+S Regeltechnik","version":"1.0","type":"link"}