% RH
Feuchtefühler mit Display in Gesamtansicht
Feuchtefühler mit Display im geschlossenen Gehäuse
Geöffneter Feuchtefühler mit Anschlussklemmen
Geöffneter Feuchtefühler mit Anschlussklemmen
Feuchtefühler mit Display und Schutzrohr
Feuchtefühler mit Display und Schutzhaube

On-wall humidity sensor / outdoor humidity sensor HYGRASGARD® AFF-U LCD

SKU 1201-7111-0400-000 EAN 4 251325 611136 Product group: WG02
In stock Available for delivery to in 3-5 business days

Country/region

Shipping calculated at checkout.
Regular price 274,16 €
Regular price Sale price 274,16 €

Auf die Merkliste

Add to wishlist

Añadir a la lista de favoritos

Aggiungi alla lista dei preferiti

Добавить в список желаний

Ajouter à la liste de souhaits

Product description

  • 0...100 % RH
  • Relative humidity [% RH]
  • 0 - 10 V
  • IP 65
Calibratable outdoor humidity/temperature transmitter HYGRASGARD® AFF / AFTF (± 2.0 %) as well as cable gland (optional M12 connector according to DIN EN 61076-2-101) and housing made of impact-resistant plastic with quick-locking screws, optionally with⁄without display.

The devices measure the relative humidity and⁄or the temperature of the air and convert the measured variables into a standard signal of 0-10 V or 4...20 mA. They have four switchable temperature ranges and are used in non-aggressive, dust-free environments, in refrigeration, air conditioning, ventilation and clean room technology. The transmitters are designed for precise humidity measurement. A digital, long-term stable sensor is used as the humidity measuring element. The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.

Technical data

Measurement relative humidity
Power supply 24 V AC (± 20 %) and
15...36 V DC
Output 0-10V
Display Yes
Output variant cable gland
Measurement range in addition to °C + %RH none
Measuring range 0...100 % RH
Features sintered filter, plastic
Output 0 - 10 V
Humidity sensor tolerance 2 %

Blog posts

Differenzdruck im Reinraum: Druckkaskaden und Sensorwahl

Differential pressure in cleanrooms: pressure c...

How is a pressure cascade created in a cleanroom? Planning guide for reference rooms, differential...

Differential pressure in cleanrooms: pressure c...

How is a pressure cascade created in a cleanroom? Planning guide for reference rooms, differentia...

Reinraumüberwachung: Sensorik für Druck, Temperatur und Feuchte

Cleanroom Monitoring: Sensors for Pressure, Tem...

What sensors are required for cleanroom monitoring? A guide to measurement tasks, measurement locations, data...

Cleanroom Monitoring: Sensors for Pressure, Tem...

What sensors are required for cleanroom monitoring? A guide to measurement tasks, measurement loc...

Temperatur in Rechenzentren überwachen: Sensorik richtig planen

Monitoring temperatures in data centers: Planni...

How temperature, humidity, dew point, and differential pressure interact: a measurement and monitoring concept for...

Monitoring temperatures in data centers: Planni...

How temperature, humidity, dew point, and differential pressure interact: a measurement and monit...

W-Modbus: Pairing Feldgerät-Gateway

W-Modbus: Pairing a Field Device with a Gateway

In this video setup guide, we'll show you how to connect a gateway to a...

W-Modbus: Pairing a Field Device with a Gateway

In this video setup guide, we'll show you how to connect a gateway to a field device via W-Modbus...

Wireless BACnet (W-BACnet) – Drahtlose Gebäudeautomation mit maximaler Flexibilität

Wireless BACnet (W-BACnet) – Wireless Building ...

Author: T. Graf The demands placed on modern building automation are constantly growing. Buildings are...

Wireless BACnet (W-BACnet) – Wireless Building ...

Author: T. Graf The demands placed on modern building automation are constantly growing. Building...

BACnet – Der offene Kommunikationsstandard

BACnet – The Open Communication Standard

Author: T. Graf Modern buildings are becoming increasingly intelligent. Sensors measure temperature, humidity, and CO₂...

BACnet – The Open Communication Standard

Author: T. Graf Modern buildings are becoming increasingly intelligent. Sensors measure temperatu...

Feuchtesensoren für Tierhaltung und Agrar

Humidity Sensors for Animal Husbandry and Agric...

In our previous post, we already explained the specific demands that high humidity and near-condensation...

Humidity Sensors for Animal Husbandry and Agric...

In our previous post, we already explained the specific demands that high humidity and near-conde...

Feuchtesensoren für Schwimmbad und Wellnessbereich

Humidity Sensors for Swimming Pools and Spa Areas

In our previous article, we described the specific challenges that high humidity, condensation, and harsh...

Humidity Sensors for Swimming Pools and Spa Areas

In our previous article, we described the specific challenges that high humidity, condensation, a...

Hochfeuchtesensorik in Industrie & Fertigung

High-Humidity Sensors in Industry & Manufacturing

In our previous post, we described the challenges that high humidity, condensation, and harsh environmental...

High-Humidity Sensors in Industry & Manufacturing

In our previous post, we described the challenges that high humidity, condensation, and harsh env...

We also manufacture individually

Do you have special requirements? As a manufacturer with our own production facilities in Germany, we are always in a position to produce products outside the standard range.

Contact us

Secure payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • Bizum
  • EPS
  • Google Pay
  • iDEAL Wero
  • Klarna
  • Maestro
  • Mastercard
  • MB WAY
  • MobilePay
  • PayPal
  • Przelewy24
  • Satispay
  • Union Pay
  • Visa

Do you have a question? We are at your disposal:

+49 911 519 470

Mo. - Fr. 7.00am - 5.00pm CEST