Search results "hygrasreg kftf"
Frost protection thermostat
THERMASREG® FST-5D-HR
1102-1022-1102-000
- Temperature limiter (with manual reset)
- –10...+15 °C/ +14...+59 °F,
factory setting w = +5 °C (+41 °F) - Switching capacity:
10 (2) A, AC 250 V;
because of the gold-plated contacts also
switching of signal voltages < 24 V - Switching differential: 2 ± 1 K (3,6 ± 1,8 °F)
- Capillary tube length: 3.0 m
- Sensor response length: approx. 40 cm
- Sensor: copper
- Permissible medium: air
- IP65
118,56 €
Duct frost protection thermostat
THERMASREG® FST-K
1102-1064-0100-001
- Temperature controllers (independently switching)
- −10...+15 °C / +14...+59 °F,
factory setting w = +5 °C (+41 °F) - 2 ± 1 K (3.6 ± 1.8 °F)
- Changeover contact
- 10 (2) A, AC 250 V;
due to the gold-plated contacts also
switching of signal voltages < 24 V - Protective tube:
made of metal, material CuZn37 (2.0321),
Ø 14 mm, NL = 205 mm - IP65
136,50 €
- Temperature controllers (independently switching)
Frost protection thermostat
THERMASREG® FST-7D-HR
1102-1025-1100-000
- Temperature limiter (with manual reset)
- –10...+15 °C/ +14...+59 °F,
factory setting w = +5 °C (+41 °F) - Switching capacity:
10 (2) A, AC 250 V;
due to the gold-plated contacts also
switching of signal voltages < 24 V - Switching differential: 2 ± 1 K (3.6 ± 1.8 °F)
- Capillary tube length: 12.0 m
- Sensing response time: approx. 40 cm
- Capillary: Copper
- Permissible medium: Air
- IP65
184,50 €
61,78 €
Frost protection thermostat
THERMASREG® FST-1D-HR
1102-1021-1100-000
- Temperature limiter (with manual reset)
- –10...+15 °C/ +14...+59 °F,
factory setting w = +5 °C (+41 °F) - Switching capacity:
10 (2) A, AC 250 V;
due to the gold-plated contacts, also
switching of signal voltages < 24 V - Switching differential: 2 ± 1 K (3.6 ± 1.8 °F)
- Capillary tube length: 6.0 m
- Sensor response length: approx. 40 cm
- Capillary: Copper
- Permissible medium: Air
- IP65
116,71 €
39,02 €
Frost protection thermostat
THERMASREG® FST-3D
1102-1023-0102-000
- Temperature controllers (independently switching)
- –10...+15 °C/ +14...+59 °F,
factory setting w = +5 °C (+41 °F) - Switching output:
10 (2) A, AC 250 V;
due to the gold-plated contacts, also
switching of signal voltages < 24 V - Switching differential: 2 ± 1 K (3.6 ± 1.8 °F)
- Capillary tube length: 1.8 m
- Sensing response length: approx. 40 cm
- Sensor: Copper
- Permissible medium: Air / Water
- IP65
101,05 €
Frost protection thermostat
THERMASREG® FST-5D
1102-1022-0102-000
- Temperature controller (self-switching)
- –10...+15 °C/ +14...+59 °F,
factory setting w = +5 °C (+41 °F) - Switching capacity:
10 (2) A, AC 250 V;
due to the gold-plated contacts also
switching of signal voltages < 24 V - Switching differential: 2 ± 1 K (3,6 ± 1,8 °F)
- Capillary tube length: 3.0 m
- Sensor response length: approx. 40 cm
- Sensor: copper
- Permissible medium: air
- IP65
96,34 €
Duct frost protection thermostat
THERMASREG® FST-K HR
1102-1064-1100-000
- Temperature limiter (with manual reset)
- –10...+15 °C/ +14...+59 °F,
factory setting w = +5 °C (+41 °F) - 2 ± 1 K (3.6 ± 1.8 °F)
- Changeover switch
- 10 (2) A, AC 250 V;
due to the gold-plated contacts also
switching of signal voltages < 24 V - Protective tube:
made of metal, material CuZn37 (2.0321),
Ø 14 mm, L = 205 mm - IP65
153,87 €
- Temperature limiter (with manual reset)
Frost protection thermostat
THERMASREG® FST-7D
1102-1025-0102-000
- Temperature controllers (independently switching)
- –10...+15 °C/ +14...+59 °F,
factory setting w = +5 °C (+41 °F) - Switching capacity:
10 (2) A, AC 250 V;
also for switching of signal voltages < 24 V due to the gold-plated contacts - Switching differential: 2 ± 1 K (3.6 ± 1.8 °F)
- Capillary tube length: 12.0 m
- Sensor response length: approx. 40 cm
- Sensor: Copper
- Permissible medium: Air
- IP65
170,72 €
Frost protection thermostat
THERMASREG® FST-8D-HR
1102-1024-1102-000
- Temperature limiter (with manual reset)
- −10...+15 °C/ +14...+59 °F,
factory setting w = +5 °C (+41 °F) - Switching capacity:
10 (2) A, AC 250 V;
due to the gold-plated contacts also
switching of signal voltages < 24 V - Switching differential: 2 ± 1 K (3.6 ± 1.8 °F)
- Capillary tube length: 0.6 m
- Sensing response length: approx. 40 cm
- Sensor: copper
- Permissible medium: air
- IP65
111,11 €