THERMASREG® KTR-090R110 1102-3010-7205-350 - Temperature controller (external setting) + safety temperature limiter
- 1. temperature range: 0...+90 °C
 2nd temperature range: +90...+110 °C
- Tmin ± 5 K; Tmax ± 3 K
- Output: Switching / changeover contact
- Switching capacity (contact load): 
 24...250 V AC +10 %, 10 A, cos ϕ = 1.0
 24...250 V AC +10 %, 1.5 A, cos ϕ = 0.6
 at 24 V at least 150 mA
- Operating medium: Air
- Thermowell: 
 made of metal, material CuZn37 (2.0321),
 Ø 14 mm, NL = 205 mm
- Installation length: approx. 205 mm (with flange);
 approx. 184 mm (without flange)
- IP65
 $137.69 $163.72 
- 
                    
THERMASREG® KTR-090090 U 1102-3010-2205-150 - Double temperature monitor (internal setting)
- 1. temperature range: 0 ... +90 °C
 2nd temperature range: 0 ... +90 °C
- Tmin ± 5 K; Tmax ± 3 K
- Output: Switching / changeover contact
- Switching capacity (contact load): 
 24...250 V AC +10 %, 10 A, cos ϕ = 1.0
 24...250 V AC +10 %, 1.5 A, cos ϕ = 0.6
 at 24 V at least 150 mA
- Operating medium: Air
- Thermowell: 
 made of metal, material CuZn37 (2.0321),
 Ø 14 mm, NL = 205 mm
- Installation length: approx. 205 mm (with flange);
 approx. 184 mm (without flange)
- IP65
 $137.69 $163.72 
- 
                    
THERMASREG® TR-04040 1102-1050-1200-200 - Temperature controller (outdoor setting) + temperature monitor (indoor setting)
- 1st temperature range: 0... +40°C
 2nd temperature range0... +40°C
- Tmin ± 3 K; Tmax ± 3 K; at +20 °C ± 1K
- Switching capacity (contact load):
 24...250 V AC +10 %, 16 A, cos ϕ = 1.0
 24...250 V AC +10 %, 1.5 A, cos ϕ = 0.6
 at 24 V at least 150 mA
- Switching differential: 2 K
- Capillary: Stainless steel, 1.4303, V2A
- IP65
 $140.22 $166.82 
- 
                    
THERMASREG® TR-04040 U 1102-1050-2200-200 - Double temperature monitor (internal setting)
- 1. temperature range: 0... +40°C
 2nd temperature range0... +40°C
- Tmin ± 3 K; Tmax ± 3 K; at +20 °C ± 1K
- Switching capacity (contact load):
 24...250 V AC +10 %, 16 A, cos ϕ = 1.0
 24...250 V AC +10 %, 1.5 A, cos ϕ = 0.6
 at 24 V at least 150 mA
- Switching differential: 2 K
- Capillary: Stainless steel, 1.4303, V2A
- IP65
 $140.22 $166.82 