Particulate matter sensors for HVAC

Which measurements do you need for your building? Our AERASGARD® particulate sensors measure PM1, PM2.5 and PM10. Depending on the model, room sensors can also measure temperature, relative humidity or CO₂. Start by identifying the mounting location and the values you need. Then check which signal your controller accepts. Models with analogue outputs or Modbus RTU are available for building automation. See the individual product pages for specifications.

Particulate sensor guide
10 products
  • Feuchte- und Temperaturfühler mit geschlossenem Gehäuse
    PM

    Room particulate matter sensor incl. humidity, temperature, particulate matter (PM) and CO2

    AERASGARD® RPS-SD

    1501-2110-1001-000

    $394.35

  • Feuchte- und Temperaturfühler mit geschlossenem Gehäuse
    °C + % RH + PM
    Si Imp Modbus

    Room sensors for humidity, temperature and PM

    AERASGARD® RFTM-PS-Modbus

    1501-2116-6001-200

    $477.13

  • Raumtemperaturfühler mit geschlossenem Gehäuse
    °C + % RH + PM

    Room sensors for humidity, temperature, particulate matter (PM) and CO2

    AERASGARD® RFTM-PS-W

    1501-2116-7301-000

    $514.42

  • Aufputz Feinstaubfühler/ Feinstaubsensor mit geschlossenem Gehäuse
    PM

    Surface-mounted fine dust sensor/ fine dust sensor

    AERASGARD® APS-SD-U

    1501-7130-1001-000

    $531.10

  • Feuchte- und Temperaturfühler mit Display
    °C + % RH + PM
    Si Imp Modbus

    Room sensors for humidity, temperature and PM

    AERASGARD® RFTM-PS-Modbus LCD

    1501-2116-6021-200

    $548.24

  • Raumtemperaturfühler mit geschlossenem Gehäuse
    °C + % RH + CO2 + PM

    Room sensors for humidity, temperature, particulate matter (PM) and CO2

    AERASGARD® RFTM-PS-CO2-W

    1501-2113-7301-000

    $598.90

  • Raumtemperaturfühler mit Display in Frontalansicht
    °C + % RH + PM

    Room sensors for humidity, temperature, particulate matter (PM) and CO2

    AERASGARD® RFTM-PS-W LCD

    1501-2116-7321-000

    $624.99

  • Raumtemperaturfühler mit Display in Frontalansicht
    °C + % RH + CO2 + PM

    Room sensors for humidity, temperature, particulate matter (PM) and CO2

    AERASGARD® RFTM-PS-CO2-W LCD

    $662.91

  • Technisches Produkt mit Display
    °C + % RH + CO2 + VOC + PM
    Si Imp Modbus

    RFTM-PS-LQ-CO2 Modbus LCD

    $787.14

What do PM1, PM2.5 and PM10 mean?

The labels refer to particle size. PM2.5 includes particles up to approximately 2.5 micrometres, while PM10 extends to about 10 micrometres. The fractions overlap. When comparing trends in a BMS, use the same fraction and unit throughout. Three PM readings from one sensor can be logged as separate time series.

In optical sensing, particles scatter light in the sensor’s measurement area. The device uses that signal to estimate concentration. Which fractions the sensor measures and reports depends on the model and configuration. For a project specification, define the outcome explicitly, such as PM2.5 in µg/m³ available as a BMS data point. This gives the designer, installer and controls engineer the same parameter to verify. APS-SD-U specifications

Which measurements does your HVAC system need?

Trend particulate concentration. If particulate matter is the only measurement required, select a sensor that delivers the specified fraction and range to the controller. For example, a room with an available analogue input might need a PM value to compare recurring peaks with operating schedules or occupancy.

Review particulate matter and room conditions together. Temperature and relative humidity provide context for room conditions. A combined room sensor is useful if the BMS needs these readings at the same point. Decide which readings need to be logged and which are only checked locally during commissioning.

Measure particles and CO₂ for ventilation. In an occupied meeting room, the CO₂ reading can feed demand-controlled ventilation. The PM value answers a separate question about airborne particles. If the BMS uses both, give each its own data point and trend. VOC measurements can provide additional information where required by the project. RFTM-PS-CO₂-W LCD specifications

  • Particulate monitoring with 0–10 V · APS-SD-U

    For indoor surface mounting and PM measurement. This model provides a 0–10 V output. Check the selected PM fraction and measurement range before configuring the analogue input.

    View AERASGARD® APS-SD-U

  • PM, temperature and humidity · RFTM-PS-Modbus

    For three readings at one room measurement point. The controller reads the available values over Modbus RTU. Check the registers for particulate matter, room temperature and relative humidity during controls engineering.

    View AERASGARD® RFTM-PS-Modbus

  • PM and CO₂ with analogue outputs · RFTM-PS-CO₂-W LCD

    For rooms that also need CO₂, temperature and relative humidity at the same location. This variant has analogue outputs, a changeover contact and a display. Use the datasheet to confirm which reading is assigned to each channel.

    View AERASGARD® RFTM-PS-CO2-W LCD

  • PM, CO₂ and VOC over Modbus · RFTM-PS-LQ-CO₂ Modbus LCD

    For projects that track PM, CO₂, VOC, temperature and relative humidity together. Specify which data points the BMS needs and how each value should be displayed.

    View RFTM-PS-LQ-CO2 Modbus LCD

0–10 V, 4–20 mA or Modbus RTU?

0–10 V works with a compatible voltage input. In an illustrative linear configuration of 0–100 µg/m³ across 0–10 V, 5 V corresponds to 50 µg/m³. Verify the actual PM fraction and range at the sensor and match the BMS input scaling. The sensor display and the BMS can then be compared on the same basis.

4–20 mA suits models with a current output and a compatible controller input. Document the supply, wiring arrangement and output assignments for the selected variant. A display helps with local checks. For trend logging, verify the value received by the BMS.

Modbus RTU is useful when the system has a compatible bus and needs more than one measurement. Record the device address, communications settings and required registers. Check scaling, units and data format when mapping points. A plausible-looking value can still represent the wrong quantity if its register or scale factor is incorrect. RFTM-PS-Modbus specifications

Plan the measurement location and commission the readings

Choose a location representative of the air in the monitored zone. A point beside a supply outlet or a local dust source can be useful for measuring that spot. A room trend may require a different position. Consider occupancy, airflow and the installation instructions. For outdoor use, check the operating conditions and enclosure rating of the selected outdoor model. S+S indoor particulate sensors

At handover, confirm the selected fraction and unit. Compare the local display, where available, with the BMS value. Record actual operating conditions, such as before and after room use, to identify unexpected jumps, fixed substitute values or point mapping errors. Follow the service and operating limits in the device instructions.

Worked application with two measurement points

A school wants to see when particle concentrations rise in a frequently used room. An analogue PM2.5 reading is sufficient for the first phase. The BMS records it alongside the ventilation schedule. If the project later adds temperature, humidity and CO₂ at the same point, the design can use more analogue inputs or switch to a combined bus sensor.

For comparisons between two rooms, use the same PM fraction, unit and comparable logging intervals. Consider how each sensor sits relative to supply air, windows and typical sources. Differences in location can affect comparisons. Record the installation details and model so that maintenance staff can interpret the readings after a replacement.

Compare the available models

Start with the measurement task, then identify the location, additional readings and interface. The AERASGARD® technical data lists the available PM readings, mounting conditions and outputs.

Compare particulate sensors
Aufputz Feinstaubfühler/ Feinstaubsensor mit geschlossenem Gehäuse

Frequently asked questions

Do I need PM2.5 or PM10 for my ventilation project?

Start with the fraction you plan to evaluate during operation. Confirm that the sensor supports it in the required mode. To log both fractions, the BMS needs separate values, labelled with their respective fractions and the same applicable concentration unit.

Can one room sensor measure particulate matter and CO₂?

Yes. The RFTM-PS-CO₂-W LCD is one example that also measures temperature and relative humidity. Check the datasheet for the readings assigned to each output. A Modbus variant can suit projects where the controller needs to retrieve several data points.

How do I choose an interface for a retrofit?

Check the existing controller inputs and wiring. A single PM value can be integrated over a suitable analogue input. To read several values over an existing bus, confirm the selected Modbus model’s communication parameters and register map against your BMS.

Which measurement range should I select?

Consider the expected concentration at the location and the resolution required in that range. Check the ranges available on the device. Document both the sensor setting and the matching BMS scale so that the transmitted signal is interpreted correctly.

Where can I find installation and maintenance instructions?

Use the operating instructions and specifications on the model’s product page. Check the mounting location, air access and permitted conditions. For sites with significant dust, humidity or outdoor exposure, confirm the model’s suitability and servicing instructions before installation.

We also manufacture individually

Do you have special requirements? As a manufacturer with our own production facilities in Germany, we are also able to produce products outside of the standard range at any time.

Contact us

Secure payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • Bizum
  • EPS
  • Google Pay
  • iDEAL Wero
  • Klarna
  • Maestro
  • Mastercard
  • MB WAY
  • MobilePay
  • PayPal
  • Przelewy24
  • Satispay
  • Union Pay
  • Visa

Do you have a question? We are at your disposal:

+49 911 519 470

Mo. - Fr. 7.00am - 5.00pm CEST