- Home
- Temperature
- Termostats
- Duct regulator & immersion regulator
Duct regulator & immersion regulator
THERMASREG® temperature regulators and stem thermometers are used to monitor, control or limit the temperature of liquid or gaseous media.
-
THERMASREG® KTR-090
1102-3010-1100-450
- Temperature controller (external setting)
- 0 ... +90 °C
- Tmin ± 5 K; Tmax ± 3 K
- Switching capacity (contact load):
24...250 V AC +10 %, 10 A, cos ϕ = 1.0
24...250 V AC +10 %, 1.5 A, cos ϕ = 0.6
at 24 V at least 150 mA - Switching differential: 3 K
- Installation length:
approx. 205 mm (with flange);
approx. 184 mm (without flange) - Protection tube:
made of metal, material CuZn37 (2.0321),
Ø 14 mm, NL = 205 mm - IP65
$92.60
$110.08
-
THERMASREG® KTR-0120
1102-3010-1100-550
- Temperature controller (external setting)
- 0 ... +120 °C
- Tmin ± 5 K; Tmax ± 3 K
- Switching capacity (contact load):
24...250 V AC +10 %, 10 A, cos ϕ = 1.0
24...250 V AC +10 %, 1.5 A, cos ϕ = 0.6
at 24 V at least 150 mA - Switching differential: 5 K
- Installation length:
approx. 205 mm (with flange);
approx. 184 mm (without flange) - Protection tube:
made of metal, material CuZn37 (2.0321),
Ø 14 mm, NL = 205 mm - IP65
$92.60
$110.08
-
THERMASREG® KTR-50140
1102-3010-1100-650
- Temperature controller (external setting)
- +50 ... +140 °C
- Tmin ± 5 K; Tmax ± 3 K
- Switching capacity (contact load):
24...250 V AC +10 %, 10 A, cos ϕ = 1.0
24...250 V AC +10 %, 1.5 A, cos ϕ = 0.6
at 24 V at least 150 mA - Switching differential: 5 K
- Installation length:
approx. 205 mm (with flange);
approx. 184 mm (without flange) - Protection tube:
made of metal, material CuZn37 (2.0321),
Ø 14 mm, NL = 205 mm - IP65
$92.60
$110.08
-
THERMASREG® KTR-060 U
1102-3010-2100-350
- Temperature monitor (internal setting)
- 0 ... +60 °C
- Tmin ± 5 K; Tmax ± 3 K
- Switching capacity (contact load):
24...250 V AC +10 %, 10 A, cos ϕ = 1.0
24...250 V AC +10 %, 1.5 A, cos ϕ = 0.6
at 24 V at least 150 mA - Switching differential: 3K
- Installation length:
approx. 205 mm (with flange);
approx. 184 mm (without flange) - Protection tube:
made of metal, material CuZn37 (2.0321),
Ø 14 mm, NL = 205 mm - IP65
$92.60
$110.08
-
THERMASREG® KTR-090 U
1102-3010-2100-450
- Temperature monitor (internal setting)
- 0 ... +90 °C
- Tmin ± 5 K; Tmax ± 3 K
- Switching capacity (contact load):
24...250 V AC +10 %, 10 A, cos ϕ = 1.0
24...250 V AC +10 %, 1.5 A, cos ϕ = 0.6
at 24 V at least 150 mA - Switching differential: 3K
- Installation length:
approx. 205 mm (with flange);
approx. 184 mm (without flange) - Protection tube:
made of metal, material CuZn37 (2.0321),
Ø 14 mm, NL = 205 mm - IP65
$92.60
$110.08
-
THERMASREG® ETR-0120 MS/200
1102-2010-1100-520
- Temperature controller (external setting)
- 0 ... +120 °C
- Tmin ± 5 K; Tmax ± 3 K
- Switching capacity (contact load):
24...250 V AC +10 %, 10 A, cos ϕ = 1.0
24...250 V AC +10 %, 1.5 A, cos ϕ = 0.6
at 24 V at least 150 mA - Switching differential: 5K
- Installation length: 200 mm
- brass
- IP65
$93.69
$111.36
-
THERMASREG® ETR-060 MS/200
1102-2010-1100-320
- Temperature controller (external setting)
- 0 ... +60 °C
- Tmin ± 5 K; Tmax ± 3 K
- Switching capacity (contact load):
24...250 V AC +10 %, 10 A, cos ϕ = 1.0
24...250 V AC +10 %, 1.5 A, cos ϕ = 0.6
at 24 V at least 150 mA - Switching differential: 3K
- Installation length: 200 mm
- brass
- IP65
$93.69
$111.36
-
THERMASREG® ETR-090 MS/200
1102-2010-1100-420
- Temperature controller (external setting)
- 0 ... +90 °C
- Tmin ± 5 K; Tmax ± 3 K
- Switching capacity (contact load):
24...250 V AC +10 %, 10 A, cos ϕ = 1.0
24...250 V AC +10 %, 1.5 A, cos ϕ = 0.6
at 24 V at least 150 mA - Switching differential: 3K
- Installation length: 200 mm
- brass
- IP65
$93.69
$111.36
-
THERMASREG® ETR-1 MS/200
1102-2010-1100-120
- Temperature controller (external setting)
- -35 ... +35 °C
- Tmin ± 5 K; Tmax ± 3 K
- Switching capacity (contact load):
24...250 V AC +10 %, 10 A, cos ϕ = 1.0
24...250 V AC +10 %, 1.5 A, cos ϕ = 0.6
at 24 V at least 150 mA - Switching differential: 3K
- Installation length: 200 mm
- brass
- IP65
$93.69
$111.36
-
THERMASREG® ETR-50140 MS/200
1102-2010-1100-620
- Temperature controller (external setting)
- +50 ... +140 °C
- Tmin ± 5 K; Tmax ± 3 K
- Switching capacity (contact load):
24...250 V AC +10 %, 10 A, cos ϕ = 1.0
24...250 V AC +10 %, 1.5 A, cos ϕ = 0.6
at 24 V at least 150 mA - Switching differential: 5K
- Installation length: 200 mm
- brass
- IP65
$93.69
$111.36
-
THERMASREG® ETR-060 U MS/200
1102-2010-2100-320
- Temperature monitor (internal setting)
- 0 ... +60 °C
- Tmin ± 5 K; Tmax ± 3 K
- Switching capacity (contact load):
24...250 V AC +10 %, 10 A, cos ϕ = 1.0
24...250 V AC +10 %, 1.5 A, cos ϕ = 0.6
at 24 V at least 150 mA - Switching differential: 3K
- Installation length: 200 mm
- brass
- IP65
$93.69
$111.36
-
THERMASREG® ETR-090 U MS/200
1102-2010-2100-420
- Temperature monitor (internal setting)
- 0 ... +90 °C
- Tmin ± 5 K; Tmax ± 3 K
- Switching capacity (contact load):
24...250 V AC +10 %, 10 A, cos ϕ = 1.0
24...250 V AC +10 %, 1.5 A, cos ϕ = 0.6
at 24 V at least 150 mA - Switching differential: 3K
- Installation length: 200 mm
- brass
- IP65
$93.69
$111.36
-
THERMASREG® TR-060-F
1102-1050-1110-300
- Temperature controller (external setting)
- 0... +60°C
- Tolerance: Tmin ± 3 K; Tmax ± 3 K
- Switching capacity (contact load):
24...250 V AC +10 %, 16 A, cos ϕ = 1.0
24...250 V AC +10 %, 1.5 A, cos ϕ = 0.6
at 24 V at least 150 mA - in immersion sleeve EL = 150 mm
- Copper tube, capillary length 1 m with PVC protective hose,
Ø 6.8 mm - IP65
$96.60
$114.84
-
THERMASREG® TR-090-F
1102-1050-1110-400
- Temperature controller (external setting)
- 0... +90°C
- Tolerance: Tmin ± 3 K; Tmax ± 3 K
- Switching capacity (contact load):
24...250 V AC +10 %, 16 A, cos ϕ = 1.0
24...250 V AC +10 %, 1.5 A, cos ϕ = 0.6
at 24 V at least 150 mA - in immersion sleeve EL = 150 mm
- Copper tube, capillary length 1 m with PVC protective hose,
Ø 6.8 mm - IP65
$96.60
$114.84
-
THERMASREG® TR-0120-F
1102-1050-1110-500
- Temperature controller (external setting)
- 0... +120°C
- Tolerance: Tmin ± 3 K; Tmax ± 3 K
- Switching capacity (contact load):
24...250 V AC +10 %, 16 A, cos ϕ = 1.0
24...250 V AC +10 %, 1.5 A, cos ϕ = 0.6
at 24 V at least 150 mA - in immersion sleeve EL = 150 mm
- Copper tube, capillary length 1 m with PVC protective hose,
Ø 6.8 mm - IP65
$96.60
$114.84
-
THERMASREG® TR-50140-F
1102-1050-1110-600
- Temperature controller (external setting)
- +50... +140°C
- Tolerance: Tmin ± 3 K; Tmax ± 3 K
- Switching capacity (contact load):
24...250 V AC +10 %, 16 A, cos ϕ = 1.0
24...250 V AC +10 %, 1.5 A, cos ϕ = 0.6
at 24 V at least 150 mA - in immersion sleeve EL = 150 mm
- Copper tube, capillary length 1 m with PVC protective hose,
Ø 6.8 mm - IP65
$96.60
$114.84
We also manufacture individually
Do you have special requirements?As a manufacturer with our own production facilities in Germany, we are always in a position to produce products outside the standard range.
Contact us
Secure payment methods
Do you have a question? We are at your disposal:
Mo. - Fr. 7.00am - 5.00pm CEST