Product description

  • 0...100 % air quality - VOC sensitivities (low/medium/high)
    0...2000 ppm / 0...5000 ppm
  • Air quality (VOC), carbon dioxide (CO2)
  • active (0 -10 V / 4...20 mA), changeover contact
  • IP 65
Patented quality product (patent no. DE 10 2014 010 719.1)

Maintenance-free duct sensor AERASGARD® KLQ-SD with active output, automatic calibration (fixed setting), in a compact plastic housing with snap-on lid, for determining the air quality or air quality in three VOC sensitivity levels (low/medium/high). The measuring transducer converts the measured variables into a standard signal of 0-10 V.

Maintenance-free duct sensor AERASGARD® KLQ-W with active/switching output, automatic calibration (can be switched off), in a compact plastic housing with quick-locking screws, for determining the air quality or air quality in three VOC sensitivity levels (low/medium/high). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable).



The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being.

The air quality is measured using a VOC sensor (mixed gas sensor for volatile organic substances). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.

Technical data

Measuring Air quality (VOC), CO2
Power supply 24 V AC/DC (± 10%)
Display No
Additional measured quantity to °C + %RH none
Measuring range 0...2000 ppm / 0...5000 ppm
Features changeover contact
Output active (0 -10 V / 4...20 mA), changeover contact

Blog posts

Wireless BACnet (W-BACnet) – Wireless Building ...

Author: T. Graf The demands placed on modern building automation are constantly growing. Buildings are...

Wireless BACnet (W-BACnet) – Wireless Building ...

Author: T. Graf The demands placed on modern building automation are constantly growing. Building...

BACnet – The Open Communication Standard

Author: T. Graf Modern buildings are becoming increasingly intelligent. Sensors measure temperature, humidity, and CO₂...

BACnet – The Open Communication Standard

Author: T. Graf Modern buildings are becoming increasingly intelligent. Sensors measure temperatu...

Humidity Sensors for Animal Husbandry and Agric...

In our previous post, we already explained the specific demands that high humidity and near-condensation...

Humidity Sensors for Animal Husbandry and Agric...

In our previous post, we already explained the specific demands that high humidity and near-conde...

Humidity Sensors for Swimming Pools and Spa Areas

In our previous article, we described the specific challenges that high humidity, condensation, and harsh...

Humidity Sensors for Swimming Pools and Spa Areas

In our previous article, we described the specific challenges that high humidity, condensation, a...

High-Humidity Sensors in Industry & Manufacturing

In our previous post, we described the challenges that high humidity, condensation, and harsh environmental...

High-Humidity Sensors in Industry & Manufacturing

In our previous post, we described the challenges that high humidity, condensation, and harsh env...

High-humidity sensors in the food industry and ...

High humidity places special demands on the sensors used in many applications. In our previous...

High-humidity sensors in the food industry and ...

High humidity places special demands on the sensors used in many applications. In our previous ar...

CuRA - Customized Register Assignment

Define Modbus registers flexibly, individually and project-specifically In building automation, it's not just precision that...

CuRA - Customized Register Assignment

Define Modbus registers flexibly, individually and project-specifically In building automation, i...

Der neue LS-Flex: Leckagen an Rohren schneller entdecken

The new LS-Flex: Detect leaks in pipes more qui...

Early detection of water leaks is now not just an option, but a necessity. With...

The new LS-Flex: Detect leaks in pipes more qui...

Early detection of water leaks is now not just an option, but a necessity. With the LS-Flex we of...

Hochfeuchte im Griff – mit diesen Spezialisten

High humidity under control – with these specia...

Perfect performance – our special solutions for extreme humidity Where other humidity sensors have long...

High humidity under control – with these specia...

Perfect performance – our special solutions for extreme humidity Where other humidity sensors hav...

Kanalfeuchtefühler im Blick: Präzise, zuverlässig, preiswert – bei jeder Messung

Duct humidity sensors in focus: Precise, reliab...

in measurement and control technology, precision and reliability are crucial - especially when it comes...

Duct humidity sensors in focus: Precise, reliab...

in measurement and control technology, precision and reliability are crucial - especially when it...

We also manufacture individually

Do you have special requirements? As a manufacturer with our own production facilities in Germany, we are always in a position to produce products outside the standard range.

Contact us

Secure payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • EPS
  • Google Pay
  • iDEAL Wero
  • Klarna
  • Maestro
  • Mastercard
  • MobilePay
  • PayPal
  • Przelewy24
  • Union Pay
  • Visa

Do you have a question? We are at your disposal:

+49 911 519 470

Mo. - Fr. 7.00am - 5.00pm CEST