New
°C
%RH
W modbus

Dew point monitors HYGRASGARD® TW-external-wModbus

SKU 1201-1281-F001-030 EAN 4 251325 647951 Product group: WG02
In stock , available in 1-3 working days
Shipping calculated at checkout.
Regular price $308.22
Regular price Sale price $308.22

Auf die Merkliste

Add to wishlist

Añadir a la lista de favoritos

Aggiungi alla lista dei preferiti

Добавить в список желаний

Ajouter à la liste de souhaits

Product description

  • –35...+80 °C
    0...100 % RH
  • Temperature [°C], relative humidity [% RH],
    dew point [°C], absolute humidity [g / m3],
    mixing ratio [g / kg], enthalpy [kJ / kg]
  • Applying sensor
  • W-Modbus
  • IP 65
Patented quality product
(prodynamic transverse convection patent no. DE 10 2012 015 726.6)

Calibratable dew point monitor HYGRASGARD® TW - Modbus - T3 (compact version incl. tensioning strap) or TW - Modbus - external (remote version), with Modbus connection, in an impact-resistant plastic housing with quick-release screws, optionally with/without display. TW - Modbus - external (remote version), with Modbus connection, in an impact-resistant plastic housing with quick-locking screws, optionally with/without display, for precise measurement of relative humidity (0...100 % RH) and temperature (-35...+80 °C) as well as for determining various humidity measurement parameters. Condensation in particular is reliably determined thanks to its patented measuring method, prodynamic transverse convection (no conductivity measurement). International system of units SI (default) can be converted to Imperial (via Modbus).

The contact sensor is used in non-aggressive, dust-free environments and is suitable for ceiling and duct mounting as well as for device installation. It is used in refrigeration, air conditioning and clean room technology, technical rooms, hotels and conference facilities.

A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The following parameters are calculated internally from these measured variables and can be called up via the Modbus: relative humidity, absolute humidity, mixing ratio, dew point temperature, enthalpy (disregarding atm. air pressure) and ambient temperature.

Innovative Modbus sensor with galvanically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in de-energized state, internal LEDs for telegram status display, two separate push-in terminals and large three-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.

Technical data

Measured values temperature, relative humidity, dew point, absolute humidity, mixing ratio, enthalpy
Power supply 24 V AC (± 20 %) and
15…36 V DC
Output W-Modbus
Display no
Protection rating IP65
Output variant cable gland
Enclosure variant external sensor
Measuring range 0...100 % RH (humidity)
-35...+80 °C (temperature)
Cable connection plastic cable gland
(M 20 x 1.5; with strain relief, replaceable,
inner diameter 8 - 13 mm) or
M12 connector according to DIN EN 610762101
(optional on request)
Communication / interface W-Modbus (Wireless Modbus with 2.4 GHz ISM)
Humidity sensor tolerance 2 %

Blog posts

Humidity Sensors for Animal Husbandry and Agric...

In our previous post, we already explained the specific demands that high humidity and near-condensation...

Humidity Sensors for Animal Husbandry and Agric...

In our previous post, we already explained the specific demands that high humidity and near-conde...

Humidity Sensors for Swimming Pools and Spa Areas

In our previous article, we described the specific challenges that high humidity, condensation, and harsh...

Humidity Sensors for Swimming Pools and Spa Areas

In our previous article, we described the specific challenges that high humidity, condensation, a...

High-Humidity Sensors in Industry & Manufacturing

In our previous post, we described the challenges that high humidity, condensation, and harsh environmental...

High-Humidity Sensors in Industry & Manufacturing

In our previous post, we described the challenges that high humidity, condensation, and harsh env...

High-humidity sensors in the food industry and ...

High humidity places special demands on the sensors used in many applications. In our previous...

High-humidity sensors in the food industry and ...

High humidity places special demands on the sensors used in many applications. In our previous ar...

CuRA - Customized Register Assignment

Define Modbus registers flexibly, individually and project-specifically In building automation, it's not just precision that...

CuRA - Customized Register Assignment

Define Modbus registers flexibly, individually and project-specifically In building automation, i...

Der neue LS-Flex: Leckagen an Rohren schneller entdecken

The new LS-Flex: Detect leaks in pipes more qui...

Early detection of water leaks is now not just an option, but a necessity. With...

The new LS-Flex: Detect leaks in pipes more qui...

Early detection of water leaks is now not just an option, but a necessity. With the LS-Flex we of...

Hochfeuchte im Griff – mit diesen Spezialisten

High humidity under control – with these specia...

Perfect performance – our special solutions for extreme humidity Where other humidity sensors have long...

High humidity under control – with these specia...

Perfect performance – our special solutions for extreme humidity Where other humidity sensors hav...

Kanalfeuchtefühler im Blick: Präzise, zuverlässig, preiswert – bei jeder Messung

Duct humidity sensors in focus: Precise, reliab...

in measurement and control technology, precision and reliability are crucial - especially when it comes...

Duct humidity sensors in focus: Precise, reliab...

in measurement and control technology, precision and reliability are crucial - especially when it...

Kanalfühler im Fokus – So steigern Sie Energieeffizienz und Betriebssicherheit

Focus on duct sensors - how to increase energy ...

In modern HVAC systems, the precise detection of humidity and temperature in the ventilation duct...

Focus on duct sensors - how to increase energy ...

In modern HVAC systems, the precise detection of humidity and temperature in the ventilation duct...

Druck im System? So behalten Sie Temperatur & Feuchte im Griff!

Pressure in the system? How to keep temperature...

Made for extreme conditions - HYGRASGARD® humidity and temperature sensors - specially developed for use...

Pressure in the system? How to keep temperature...

Made for extreme conditions - HYGRASGARD® humidity and temperature sensors - specially developed ...

We also manufacture individually

Do you have special requirements? As a manufacturer with our own production facilities in Germany, we are always in a position to produce products outside the standard range.

Contact us

Secure payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • EPS
  • Google Pay
  • iDEAL Wero
  • Klarna
  • Maestro
  • Mastercard
  • MobilePay
  • PayPal
  • Przelewy24
  • Union Pay
  • Visa

Do you have a question? We are at your disposal:

+49 911 519 470

Mo. - Fr. 7.00am - 5.00pm CEST