New
°C + % RH + VOC
SI IMP W-Modbus W-BACnet
WIRELESS Raumregler in Gesamtansicht mit Display
WIRELESS Raumregler in Frontalansicht mit Display
WIRELESS Raumregler mit Anschlussdiagramm
WIRELESS Raumregler in Seitenansicht
WIRELESS Raumregler mit verschiedenen Gehäuseoberflächen
WIRELESS Raumregler mit verschiedenen Flaggenmotiven

WIRELESS room controller (controller) Rymaskon® RYM 1451C-THV-OTFS-WM-FM-W

SKU RYM1-4511-W720-000 EAN 4 251325 626086 Product group: WG02
In stock , available in 3-5 working days
Shipping calculated at checkout.
Regular price $516.88
Regular price Sale price $516.88

Auf die Merkliste

Add to wishlist

Añadir a la lista de favoritos

Aggiungi alla lista dei preferiti

Добавить в список желаний

Ajouter à la liste de souhaits

Product description

Rymaskon® 1000 C Controller - 230V
  • Temperature [°C] [°F],
    relative humidity [% RH],
    air quality (VOC) [%] [pbb]
  • Control: temperature, fan
  • Output: W-Modbus (RTU) / W-BACnet (MS/TP), 0-10V, switching
  • Input: 1x NTC10K, 1x digital
  • Power supply: 230 V AC
  • Flush-mount installation
  • IP30
The room controllers of the Rymaskon® 1000 series are designed for controlling residential, hotel and office rooms and regulate the indoor heating, cooling and fan stages individually. The product family stands out for its elegant design, intuitive operation and the wide range of combination options of the individual components.

The Rymaskon® 1000 room controller are used to control and regulate heating convectors and fan coil units (fancoil). Depending on the type variant, the units are available with analog outputs (0 -10 V) as well as with digital / relay outputs for controlling heating valves, cooling valves, 6-way valves, staged fan motors or EC fan motors. Control is carried out via PI, PWM or 2-/3-point control. With the changeover function, 2- and 4-pipe systems can be operated. Communication is optionally carried out via Modbus (RTU) / BACnet (MS/TP) wired, or wirelessly via W-Modbus / W-BACnet (Wireless).

In addition to the integrated temperature and humidity sensor, sensors for CO2 and VOC are available as options. Furthermore, an input is provided for a passive temperature sensor (NTC10K) and an input for a potential-free contact. This makes it possible, for example, to connect a window contact or a condensation monitor. This provides all options to flexibly and individually climate the rooms.

In addition, the functions for solar shading (roller shutters, blinds) or lighting (with dimming function) can be controlled via the bus. The optical indication is provided via a 2" TFT display, and operation is via capacitive keys (touchkeys). All device types are available in the timeless Iduna 3 enclosure (112 x 89.5 x 24 mm) in white or black. Wall mounting is done on standard flush-mounted back boxes.

Technical data

Function type Controller
Measured variables Temperature, relative humidity, air quality (VOC)
Communication W-Modbus / W-BACnet
Power supply 230 V AC (100-240 V AC)
Color White
Display Yes
Ingress protection rating IP30
Measured variable in addition to °C + %RH + VOC
Output W-Modbus / W-BACnet
Communication/ interface
Transmission method depends on the device type (wired or wireless),
protocol is configurable (can be switched via the bus; bus parameters remain unchanged)

Wireless
Radio module (AES-128 encrypted), max. 100 devices (per gateway),
frequency 2.4 GHz ISM, transmit power 100 mW
Range max. 500 m (open field) / approx. 50 - 70 m (building)
  • W-Modbus (Wireless Modbus), slave, address range 1…247

  • W-BACnet (Wireless BACnet), master, address range 0…127

Blog posts

W-Modbus: Pairing Feldgerät-Gateway

W-Modbus: Pairing a Field Device with a Gateway

In this video setup guide, we'll show you how to connect a gateway to a...

W-Modbus: Pairing a Field Device with a Gateway

In this video setup guide, we'll show you how to connect a gateway to a field device via W-Modbus...

Wireless BACnet (W-BACnet) – Drahtlose Gebäudeautomation mit maximaler Flexibilität

Wireless BACnet (W-BACnet) – Wireless Building ...

Author: T. Graf The demands placed on modern building automation are constantly growing. Buildings are...

Wireless BACnet (W-BACnet) – Wireless Building ...

Author: T. Graf The demands placed on modern building automation are constantly growing. Building...

BACnet – Der offene Kommunikationsstandard

BACnet – The Open Communication Standard

Author: T. Graf Modern buildings are becoming increasingly intelligent. Sensors measure temperature, humidity, and CO₂...

BACnet – The Open Communication Standard

Author: T. Graf Modern buildings are becoming increasingly intelligent. Sensors measure temperatu...

Feuchtesensoren für Tierhaltung und Agrar

Humidity Sensors for Animal Husbandry and Agric...

In our previous post, we already explained the specific demands that high humidity and near-condensation...

Humidity Sensors for Animal Husbandry and Agric...

In our previous post, we already explained the specific demands that high humidity and near-conde...

Feuchtesensoren für Schwimmbad und Wellnessbereich

Humidity Sensors for Swimming Pools and Spa Areas

In our previous article, we described the specific challenges that high humidity, condensation, and harsh...

Humidity Sensors for Swimming Pools and Spa Areas

In our previous article, we described the specific challenges that high humidity, condensation, a...

Hochfeuchtesensorik in Industrie & Fertigung

High-Humidity Sensors in Industry & Manufacturing

In our previous post, we described the challenges that high humidity, condensation, and harsh environmental...

High-Humidity Sensors in Industry & Manufacturing

In our previous post, we described the challenges that high humidity, condensation, and harsh env...

Hochfeuchtesensorik in Lebensmittelindustrie & Hygienebereiche

High-humidity sensors in the food industry and ...

High humidity places special demands on the sensors used in many applications. In our previous...

High-humidity sensors in the food industry and ...

High humidity places special demands on the sensors used in many applications. In our previous ar...

Feuchte- und Temperaturfühler für aggressive Umgebungen (AFTF-45 / KFTF-45)

Humidity and Temperature Sensors for Harsh Envi...

Author: S. Becker In many applications, humidity is not the actual problem—it is air quality....

Humidity and Temperature Sensors for Harsh Envi...

Author: S. Becker In many applications, humidity is not the actual problem—it is air quality. Che...

Hochfeuchte Sensorik für Pharma & temperaturgeführte Logistik

High-humidity sensors for the pharmaceutical in...

In this article, we’ve explained in detail why humidity measurement is essential under high-humidity conditions...

High-humidity sensors for the pharmaceutical in...

In this article, we’ve explained in detail why humidity measurement is essential under high-humid...

We also manufacture individually

Do you have special requirements? As a manufacturer with our own production facilities in Germany, we are always in a position to produce products outside the standard range.

Contact us

Secure payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • EPS
  • Google Pay
  • iDEAL Wero
  • Klarna
  • Maestro
  • Mastercard
  • MobilePay
  • PayPal
  • Przelewy24
  • Union Pay
  • Visa

Do you have a question? We are at your disposal:

+49 911 519 470

Mo. - Fr. 7.00am - 5.00pm CEST