New
°C + % RH
SI IMP Modbus BACnet
Raumregler mit Display in Gesamtansicht
Raumregler mit Display in Frontalansicht
Raumregler im Anwendungsschema
Raumregler im Anschlussplan
Raumregler mit Display in verschiedenen Designs
Raumregler mit Display in verschiedenen Oberflächendesigns
Raumregler in Seitenansicht

Room controller (controller) Rymaskon® RYM 1321C-TH-OTBS-M-FM-W

SKU RYM1-3211-M210-001 EAN 4 251325 644561 Product group: WG02
In stock , available in 3-5 working days
Shipping calculated at checkout.
Regular price $346.81
Regular price Sale price $346.81

Auf die Merkliste

Add to wishlist

Añadir a la lista de favoritos

Aggiungi alla lista dei preferiti

Добавить в список желаний

Ajouter à la liste de souhaits

Product description

Rymaskon® 1000 C Controller - 24V
  • Temperature [°C] [°F],
    relative humidity [% RH]
  • Control: Temperature, solar shading
  • Output: Modbus RTU / BACnet (MS/TP), 0-10V
  • Input: 1x NTC10K, 1x digital
  • Power supply: 24 V AC / DC
  • Flush-mount installation
  • IP30
The Rymaskon® 1000 series room control units are designed for use in residential, hotel, and office spaces and individually regulate the heating, cooling, and fan settings for the interior. The product family is characterized by its elegant design, intuitive operation, and the wide range of possible combinations of individual components.

The Rymaskon® 1000 room control units are used to control and regulate heating convectors and fan coil units. Depending on the model variant, the units are available with analog outputs (0–10 V) as well as digital/relay outputs for controlling heating valves, cooling valves, 6-way valves, multi-speed fans, or EC fans. Control is achieved via PI, PWM, or 2-/3-point control. The changeover function allows for the operation of 2- and 4-pipe systems. Communication is available either via wired Modbus (RTU) / BACnet (MS/TP) or wirelessly via W-Modbus / W-BACnet (Wireless).

In addition to the integrated temperature and humidity sensor, optional sensors for CO2 and VOC are available. Furthermore, there is an input for a passive temperature sensor (NTC10K) and an input for a potential-free contact. This allows, for example, a window contact or a condensation monitor to be connected. As a result, all options are available for flexibly and individually climate-controlling rooms.

In addition, functions such as sun protection (venetian blinds, roller shades) or lighting (with dimming function) can be controlled via the bus. Visual feedback is provided by a 2" TFT display, and operation is via capacitive touch keys. All device types are available in the timeless Iduna 3 housing (112 x 89.5 x 24 mm) in white or black. Wall mounting is performed using standard flush-mounted boxes.

Technical data

Function type Controller
Measured variables Temperature, relative humidity
Communication Modbus RTU / BACnet
Power supply 24 V AC/DC (± 10 %)
Color White
Display Yes
Measured quantity in addition to °C + %RH Only °C + % RH
Output Modbus RTU / BACnet
Communication/ Interface
 The transmission method depends on the device type (wired or wireless),
the protocol is configurable (switchable via bus; bus parameters remain unchanged)

Wired
RS 485 interface, galvanically isolated, max. 32 devices,
  • Modbus (RTU), Slave, address range 1–247

(9600 / 19200 / 38400 / 57600 / 115200 baud, 8N1, even/odd parity, 1/2 stop bits)
  • BACnet (MS/TP), Master, address range 0–127

(9600 / 19200 / 38400 / 57600 / 115200 baud, 8N1, 1 stop bit)

Blog posts

W-Modbus: Pairing Feldgerät-Gateway

W-Modbus: Pairing a Field Device with a Gateway

In this video setup guide, we'll show you how to connect a gateway to a...

W-Modbus: Pairing a Field Device with a Gateway

In this video setup guide, we'll show you how to connect a gateway to a field device via W-Modbus...

Wireless BACnet (W-BACnet) – Drahtlose Gebäudeautomation mit maximaler Flexibilität

Wireless BACnet (W-BACnet) – Wireless Building ...

Author: T. Graf The demands placed on modern building automation are constantly growing. Buildings are...

Wireless BACnet (W-BACnet) – Wireless Building ...

Author: T. Graf The demands placed on modern building automation are constantly growing. Building...

BACnet – Der offene Kommunikationsstandard

BACnet – The Open Communication Standard

Author: T. Graf Modern buildings are becoming increasingly intelligent. Sensors measure temperature, humidity, and CO₂...

BACnet – The Open Communication Standard

Author: T. Graf Modern buildings are becoming increasingly intelligent. Sensors measure temperatu...

Feuchtesensoren für Tierhaltung und Agrar

Humidity Sensors for Animal Husbandry and Agric...

In our previous post, we already explained the specific demands that high humidity and near-condensation...

Humidity Sensors for Animal Husbandry and Agric...

In our previous post, we already explained the specific demands that high humidity and near-conde...

Feuchtesensoren für Schwimmbad und Wellnessbereich

Humidity Sensors for Swimming Pools and Spa Areas

In our previous article, we described the specific challenges that high humidity, condensation, and harsh...

Humidity Sensors for Swimming Pools and Spa Areas

In our previous article, we described the specific challenges that high humidity, condensation, a...

Hochfeuchtesensorik in Industrie & Fertigung

High-Humidity Sensors in Industry & Manufacturing

In our previous post, we described the challenges that high humidity, condensation, and harsh environmental...

High-Humidity Sensors in Industry & Manufacturing

In our previous post, we described the challenges that high humidity, condensation, and harsh env...

Hochfeuchtesensorik in Lebensmittelindustrie & Hygienebereiche

High-humidity sensors in the food industry and ...

High humidity places special demands on the sensors used in many applications. In our previous...

High-humidity sensors in the food industry and ...

High humidity places special demands on the sensors used in many applications. In our previous ar...

Feuchte- und Temperaturfühler für aggressive Umgebungen (AFTF-45 / KFTF-45)

Humidity and Temperature Sensors for Harsh Envi...

Author: S. Becker In many applications, humidity is not the actual problem—it is air quality....

Humidity and Temperature Sensors for Harsh Envi...

Author: S. Becker In many applications, humidity is not the actual problem—it is air quality. Che...

Hochfeuchte Sensorik für Pharma & temperaturgeführte Logistik

High-humidity sensors for the pharmaceutical in...

In this article, we’ve explained in detail why humidity measurement is essential under high-humidity conditions...

High-humidity sensors for the pharmaceutical in...

In this article, we’ve explained in detail why humidity measurement is essential under high-humid...

We also manufacture individually

Do you have special requirements? As a manufacturer with our own production facilities in Germany, we are always in a position to produce products outside the standard range.

Contact us

Secure payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • EPS
  • Google Pay
  • iDEAL Wero
  • Klarna
  • Maestro
  • Mastercard
  • MobilePay
  • PayPal
  • Przelewy24
  • Union Pay
  • Visa

Do you have a question? We are at your disposal:

+49 911 519 470

Mo. - Fr. 7.00am - 5.00pm CEST