New
°C + % RH
SI IMP W-Modbus W-BACnet
WIRELESS Raumregler in Gesamtansicht mit Display
WIRELESS Raumregler in Frontalansicht mit Display
WIRELESS Raumregler mit Anschlussdiagramm für Stellventile
WIRELESS Raumregler mit Anschlussdiagramm für ein 6-Wege-Ventil
WIRELESS Raumregler mit verschiedenen Frontdesigns
WIRELESS Raumregler mit verschiedenen Oberflächen
WIRELESS Raumregler in Seitenansicht

WIRELESS room controller (controller) Rymaskon® RYM 1322C-TH-OTBS-WM-FM-B

SKU RYM1-3221-W210-001 EAN 4 251325 644325 Product group: WG02
In stock , available in 3-5 working days
Shipping calculated at checkout.
Regular price $443.65
Regular price Sale price $443.65

Auf die Merkliste

Add to wishlist

Añadir a la lista de favoritos

Aggiungi alla lista dei preferiti

Добавить в список желаний

Ajouter à la liste de souhaits

Product description

Rymaskon® 1000 C Controller - 24V
  • Temperature [°C] [°F],
    relative humidity [% RH]
  • Control: Temperature, solar shading
  • Output: W-Modbus (RTU) / W-BACnet (MS/TP), 0-10V
  • Input: 1x NTC10K, 1x digital
  • Power supply: 24 V AC / DC
  • Flush-mounting
  • IP30
The room controller devices of the Rymaskon® 1000 series are designed for controlling residential, hotel and office rooms and individually regulate the heating, cooling and fan stages of the indoor area. The product family is distinguished by its elegant design, intuitive operation and the many possible combinations of the individual components.

The Rymaskon® 1000 room controller devices serve for controlling and regulating heating fan convectors and fan-coil units. Depending on the model variant, the devices are available with analog outputs (0 -10 V) as well as with digital/relay outputs, for controlling heating valves, cooling valves, 6-way valves, staged dampers or EC dampers. Control is carried out via PI, PWM or 2-/3-point control. With the changeover function, 2-pipe and 4-pipe systems can be operated. Communication is available either wired via Modbus (RTU) / BACnet (MS/TP) or wirelessly via W-Modbus / W-BACnet (Wireless).

In addition to the integrated temperature and humidity sensor, sensors for CO2 and VOC are available as options. Furthermore, an input for a passive temperature sensor (NTC10K) and an input for a potential-free contact are provided. For example, a window contact or a condensation monitor can be connected. This ensures all options are available to flexibly and individually condition rooms.

In addition, sun protection (roller shutters, blinds) or lighting (with dimming function) can be controlled via the bus. The optical indication is provided via a 2" TFT display, and operation via capacitive buttons (touchkeys). All device types are available in the timeless Iduna 3 housing (112 x 89.5 x 24 mm) in white or black. Wall mounting is performed on standard flush-mount back boxes.

Technical data

Type of function Controller
Measured variables Temperature, relative humidity
Communication W-Modbus / W-BACnet
Power supply 24 V AC/DC (± 10%)
Color Black
Display Yes
Ingress protection rating IP30
Measured variable additionally to °C + % RH Only °C + % RH
Output W-Modbus / W-BACnet
Communication/Interface
The transmission method depends on the device type (wired or wireless),
the protocol is configurable (switchable via the bus, bus parameters remain unchanged)

Wireless
Radio module (AES-128 encrypted), max. 100 devices (per gateway),
frequency 2.4 GHz ISM, transmit power 100 mW
Range max. 500 m (open field) / approx. 50 - 70 m (building)
  • W-Modbus (Wireless Modbus), Slave, address range 1–247

  • W-BACnet (Wireless BACnet), Master, address range 0–127

Blog posts

W-Modbus: Pairing Feldgerät-Gateway

W-Modbus: Pairing a Field Device with a Gateway

In this video setup guide, we'll show you how to connect a gateway to a...

W-Modbus: Pairing a Field Device with a Gateway

In this video setup guide, we'll show you how to connect a gateway to a field device via W-Modbus...

Wireless BACnet (W-BACnet) – Drahtlose Gebäudeautomation mit maximaler Flexibilität

Wireless BACnet (W-BACnet) – Wireless Building ...

Author: T. Graf The demands placed on modern building automation are constantly growing. Buildings are...

Wireless BACnet (W-BACnet) – Wireless Building ...

Author: T. Graf The demands placed on modern building automation are constantly growing. Building...

BACnet – Der offene Kommunikationsstandard

BACnet – The Open Communication Standard

Author: T. Graf Modern buildings are becoming increasingly intelligent. Sensors measure temperature, humidity, and CO₂...

BACnet – The Open Communication Standard

Author: T. Graf Modern buildings are becoming increasingly intelligent. Sensors measure temperatu...

Feuchtesensoren für Tierhaltung und Agrar

Humidity Sensors for Animal Husbandry and Agric...

In our previous post, we already explained the specific demands that high humidity and near-condensation...

Humidity Sensors for Animal Husbandry and Agric...

In our previous post, we already explained the specific demands that high humidity and near-conde...

Feuchtesensoren für Schwimmbad und Wellnessbereich

Humidity Sensors for Swimming Pools and Spa Areas

In our previous article, we described the specific challenges that high humidity, condensation, and harsh...

Humidity Sensors for Swimming Pools and Spa Areas

In our previous article, we described the specific challenges that high humidity, condensation, a...

Hochfeuchtesensorik in Industrie & Fertigung

High-Humidity Sensors in Industry & Manufacturing

In our previous post, we described the challenges that high humidity, condensation, and harsh environmental...

High-Humidity Sensors in Industry & Manufacturing

In our previous post, we described the challenges that high humidity, condensation, and harsh env...

Hochfeuchtesensorik in Lebensmittelindustrie & Hygienebereiche

High-humidity sensors in the food industry and ...

High humidity places special demands on the sensors used in many applications. In our previous...

High-humidity sensors in the food industry and ...

High humidity places special demands on the sensors used in many applications. In our previous ar...

Feuchte- und Temperaturfühler für aggressive Umgebungen (AFTF-45 / KFTF-45)

Humidity and Temperature Sensors for Harsh Envi...

Author: S. Becker In many applications, humidity is not the actual problem—it is air quality....

Humidity and Temperature Sensors for Harsh Envi...

Author: S. Becker In many applications, humidity is not the actual problem—it is air quality. Che...

Hochfeuchte Sensorik für Pharma & temperaturgeführte Logistik

High-humidity sensors for the pharmaceutical in...

In this article, we’ve explained in detail why humidity measurement is essential under high-humidity conditions...

High-humidity sensors for the pharmaceutical in...

In this article, we’ve explained in detail why humidity measurement is essential under high-humid...

We also manufacture individually

Do you have special requirements? As a manufacturer with our own production facilities in Germany, we are always in a position to produce products outside the standard range.

Contact us

Secure payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • EPS
  • Google Pay
  • iDEAL Wero
  • Klarna
  • Maestro
  • Mastercard
  • MobilePay
  • PayPal
  • Przelewy24
  • Union Pay
  • Visa

Do you have a question? We are at your disposal:

+49 911 519 470

Mo. - Fr. 7.00am - 5.00pm CEST