New
°C + % RH + VOC
SI IMP Modbus BACnet
Raumregler mit Display in Gesamtansicht
Raumregler mit Display in Frontalansicht
Raumregler mit Anschlussdiagramm für Lüfter und Stellventile
Raumregler mit Anschlussdiagramm für Klappenstellantrieb und Ventil
Raumregler mit dekorativen Flaggenoberflächen
Raumregler mit dekorativen Oberflächen
Raumregler in Seitenansicht

Room controllers (controllers) Rymaskon® RYM 1432C-THV-OTFS-M-FM-B

SKU RYM1-4321-M710-000 EAN 4 251325 626871 Product group: WG02
In stock , available in 3-5 working days
Shipping calculated at checkout.
Regular price $420.05
Regular price Sale price $420.05

Auf die Merkliste

Add to wishlist

Añadir a la lista de favoritos

Aggiungi alla lista dei preferiti

Добавить в список желаний

Ajouter à la liste de souhaits

Product description

Rymaskon® 1000 C Controller - 24V
  • Temperature [°C] [°F],
    relative humidity [% RH],
    air quality (VOC) [%] [pbb]
  • Control: Temperature, fan
  • Output: Modbus RTU / BACnet (MS/TP), 0-10V
  • Input: 1x NTC10K, 1x digital
  • Power supply: 24 V AC / DC
  • Flush-mount installation
  • IP30
The room controllers of the Rymaskon® 1000 series are designed for controlling residential, hotel and office rooms and individually regulate the heating, cooling and fan stages of the interior space. The product family stands out for its elegant design, intuitive operation and the many configuration options offered by the individual components.

The room controller Rymaskon® 1000 controllers are used to control and regulate heating fan coil units and chilled water fan coil units (fan coil). Depending on the model variant, the units are available with analog outputs (0 -10 V) as well as with digital / relay outputs, for actuating heating valves, cooling valves, 6-way valves, staged fans or EC fans. Control is performed via PI, PWM or 2-/3-point control. With the changeover function, 2-pipe and 4-pipe systems can be operated. Communication is either wired via Modbus (RTU) / BACnet (MS/TP) or wirelessly via W-Modbus / W-BACnet (Wireless).

In addition to the integrated temperature and humidity sensor, sensors for CO2 and VOC are optionally available. In addition, an input for a passive temperature sensor (NTC10K) and an input for a potential-free contact are provided. This makes it possible, for example, to connect a window contact or a condensation switch. This ensures all options are available to flexibly and individually condition rooms.

In addition, the functions for solar shading (roller shutters, blinds) or lighting (with dimming function) can be controlled via the bus. The optical display is provided by a 2" TFT display, and operation is via capacitive keys (Touchkeys). All device types are available in the timeless Iduna 3 enclosure (112 x 89,5 x 24 mm) in white or black. Wall mounting is on standard flush-mounting boxes.

Technical data

Function type Controller
Measured variables Temperature, relative humidity, air quality (VOC)
Communication Modbus RTU / BACnet
Power supply 24 V AC/DC (± 10 %)
Color Black
Display Yes
Measurement quantity in addition to °C + %RH + VOC
Output Modbus RTU / BACnet
Communication/ interface
Transmission method depends on the device type (wired or wireless),
protocol is configurable (switchable via bus; bus parameters remain unchanged)

Wired
RS 485 interface, galvanically isolated, max. 32 devices,
  • Modbus (RTU), slave, address range 1‖247

(9600 / 19200 / 38400 / 57600 / 115200 baud, 8N1, even/odd parity, 1/2 stop bits)
  • BACnet (MS/TP), master, address range 0‖127

(9600 / 19200 / 38400 / 57600 / 115200 baud, 8N1, 1 stop bit)

Blog posts

W-Modbus: Pairing Feldgerät-Gateway

W-Modbus: Pairing a Field Device with a Gateway

In this video setup guide, we'll show you how to connect a gateway to a...

W-Modbus: Pairing a Field Device with a Gateway

In this video setup guide, we'll show you how to connect a gateway to a field device via W-Modbus...

Wireless BACnet (W-BACnet) – Drahtlose Gebäudeautomation mit maximaler Flexibilität

Wireless BACnet (W-BACnet) – Wireless Building ...

Author: T. Graf The demands placed on modern building automation are constantly growing. Buildings are...

Wireless BACnet (W-BACnet) – Wireless Building ...

Author: T. Graf The demands placed on modern building automation are constantly growing. Building...

BACnet – Der offene Kommunikationsstandard

BACnet – The Open Communication Standard

Author: T. Graf Modern buildings are becoming increasingly intelligent. Sensors measure temperature, humidity, and CO₂...

BACnet – The Open Communication Standard

Author: T. Graf Modern buildings are becoming increasingly intelligent. Sensors measure temperatu...

Feuchtesensoren für Tierhaltung und Agrar

Humidity Sensors for Animal Husbandry and Agric...

In our previous post, we already explained the specific demands that high humidity and near-condensation...

Humidity Sensors for Animal Husbandry and Agric...

In our previous post, we already explained the specific demands that high humidity and near-conde...

Feuchtesensoren für Schwimmbad und Wellnessbereich

Humidity Sensors for Swimming Pools and Spa Areas

In our previous article, we described the specific challenges that high humidity, condensation, and harsh...

Humidity Sensors for Swimming Pools and Spa Areas

In our previous article, we described the specific challenges that high humidity, condensation, a...

Hochfeuchtesensorik in Industrie & Fertigung

High-Humidity Sensors in Industry & Manufacturing

In our previous post, we described the challenges that high humidity, condensation, and harsh environmental...

High-Humidity Sensors in Industry & Manufacturing

In our previous post, we described the challenges that high humidity, condensation, and harsh env...

Hochfeuchtesensorik in Lebensmittelindustrie & Hygienebereiche

High-humidity sensors in the food industry and ...

High humidity places special demands on the sensors used in many applications. In our previous...

High-humidity sensors in the food industry and ...

High humidity places special demands on the sensors used in many applications. In our previous ar...

Feuchte- und Temperaturfühler für aggressive Umgebungen (AFTF-45 / KFTF-45)

Humidity and Temperature Sensors for Harsh Envi...

Author: S. Becker In many applications, humidity is not the actual problem—it is air quality....

Humidity and Temperature Sensors for Harsh Envi...

Author: S. Becker In many applications, humidity is not the actual problem—it is air quality. Che...

Hochfeuchte Sensorik für Pharma & temperaturgeführte Logistik

High-humidity sensors for the pharmaceutical in...

In this article, we’ve explained in detail why humidity measurement is essential under high-humidity conditions...

High-humidity sensors for the pharmaceutical in...

In this article, we’ve explained in detail why humidity measurement is essential under high-humid...

We also manufacture individually

Do you have special requirements? As a manufacturer with our own production facilities in Germany, we are always in a position to produce products outside the standard range.

Contact us

Secure payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • EPS
  • Google Pay
  • iDEAL Wero
  • Klarna
  • Maestro
  • Mastercard
  • MobilePay
  • PayPal
  • Przelewy24
  • Union Pay
  • Visa

Do you have a question? We are at your disposal:

+49 911 519 470

Mo. - Fr. 7.00am - 5.00pm CEST