New
°C + % RH + CO2
SI IMP W-Modbus W-BACnet
WIRELESS Raumregler in Gesamtansicht mit Display
WIRELESS Raumregler in Frontalansicht mit Display
WIRELESS Raumregler in Seitenansicht
WIRELESS Raumregler mit verschiedenen farbigen Oberflächenvarianten
WIRELESS Raumregler mit verschiedenen strukturierten Oberflächenvarianten

WIRELESS room controller (controller) Rymaskon® RYM 1462C-THC-OTFS-WM-FM-B

SKU RYM1-4621-W610-000 EAN 4 251325 625522 Product group: WG02
In stock , available in 3-5 working days
Shipping calculated at checkout.
Regular price $520.62
Regular price Sale price $520.62

Auf die Merkliste

Add to wishlist

Añadir a la lista de favoritos

Aggiungi alla lista dei preferiti

Добавить в список желаний

Ajouter à la liste de souhaits

Product description

Rymaskon® 1000 C Controller - 24V
  • Temperature [°C] [°F],
    relative humidity [% RH],
    carbon dioxide (CO2) [ppm]
  • Control: Temperature, fans
  • Output: W-Modbus (RTU) / W-BACnet (MS/TP), 0-10V, switching contacts
  • Input: 1x NTC10K, 1x digital
  • Power supply: 24 V AC / DC
  • Flush-mount installation
  • IP30
The room controller devices of the series Rymaskon® 1000 are designed for controlling residential, hotel and office rooms and individually regulate the indoor heating, cooling and ventilation stages. The product family stands out for its elegant design, intuitive operation and the many combination options of the individual components.

The room controller Rymaskon® 1000 controllers are used to drive and control heating fan coil units and blower fan coil units (fan coil). Depending on the type variant, the devices are available with analogue outputs (0 -10 V) as well as with digital / relay outputs for controlling heating valves, cooling valves, 6-way valves, stepped vents or EC vents. The control is performed via PI, PWM or 2-/3-point control. With the Changeover function, 2-pipe and 4-pipe systems can be operated. Communication is optionally available via wired Modbus (RTU) / BACnet (MS/TP) or wirelessly via W-Modbus / W-BACnet (Wireless).

In addition to the integrated temperature and humidity sensor, sensors for CO2 and VOC are available as options. Furthermore, an input for a passive temperature sensor (NTC10K) and an input for a potential-free contact are provided. For example, a window contact or a condensate monitor can be connected. This means all options are available to flexibly and individually climate-control the rooms.

In addition, the bus can be used to control shading functions (roller shutters, blinds) or lighting (with dimming function). The visual indication is provided via a 2" TFT display, and operation is via capacitive keys (Touchkeys). All device types are available in the timeless Iduna 3 housing (112 x 89.5 x 24 mm) in the colors white or black. Wall mounting is done on standard flush-mount boxes.

Technical data

Type of function Controller
Measured variables Temperature, relative humidity, CO2
Communication W-Modbus / W-BACnet
Power supply 24 V AC/DC (± 10%)
Color Black
Display Yes
Measurement quantity in addition to °C + %RH + CO2
Output W-Modbus / W-BACnet
Communication / interface
Transmission method depends on the device type (wired or wireless),
protocol is configurable (switchable via bus; bus parameters remain unchanged)

Wireless
radio module (AES-128 encrypted), max. 100 devices (per gateway),
frequency 2.4 GHz ISM, transmit power 100 mW
Range max. 500 m (open field) / approx. 50 - 70 m (building)
  • W-Modbus (Wireless Modbus), slave, address range 1…247

  • W-BACnet (Wireless BACnet), master, address range 0…127

Blog posts

W-Modbus: Pairing Feldgerät-Gateway

W-Modbus: Pairing a Field Device with a Gateway

In this video setup guide, we'll show you how to connect a gateway to a...

W-Modbus: Pairing a Field Device with a Gateway

In this video setup guide, we'll show you how to connect a gateway to a field device via W-Modbus...

Wireless BACnet (W-BACnet) – Drahtlose Gebäudeautomation mit maximaler Flexibilität

Wireless BACnet (W-BACnet) – Wireless Building ...

Author: T. Graf The demands placed on modern building automation are constantly growing. Buildings are...

Wireless BACnet (W-BACnet) – Wireless Building ...

Author: T. Graf The demands placed on modern building automation are constantly growing. Building...

BACnet – Der offene Kommunikationsstandard

BACnet – The Open Communication Standard

Author: T. Graf Modern buildings are becoming increasingly intelligent. Sensors measure temperature, humidity, and CO₂...

BACnet – The Open Communication Standard

Author: T. Graf Modern buildings are becoming increasingly intelligent. Sensors measure temperatu...

Feuchtesensoren für Tierhaltung und Agrar

Humidity Sensors for Animal Husbandry and Agric...

In our previous post, we already explained the specific demands that high humidity and near-condensation...

Humidity Sensors for Animal Husbandry and Agric...

In our previous post, we already explained the specific demands that high humidity and near-conde...

Feuchtesensoren für Schwimmbad und Wellnessbereich

Humidity Sensors for Swimming Pools and Spa Areas

In our previous article, we described the specific challenges that high humidity, condensation, and harsh...

Humidity Sensors for Swimming Pools and Spa Areas

In our previous article, we described the specific challenges that high humidity, condensation, a...

Hochfeuchtesensorik in Industrie & Fertigung

High-Humidity Sensors in Industry & Manufacturing

In our previous post, we described the challenges that high humidity, condensation, and harsh environmental...

High-Humidity Sensors in Industry & Manufacturing

In our previous post, we described the challenges that high humidity, condensation, and harsh env...

Hochfeuchtesensorik in Lebensmittelindustrie & Hygienebereiche

High-humidity sensors in the food industry and ...

High humidity places special demands on the sensors used in many applications. In our previous...

High-humidity sensors in the food industry and ...

High humidity places special demands on the sensors used in many applications. In our previous ar...

Feuchte- und Temperaturfühler für aggressive Umgebungen (AFTF-45 / KFTF-45)

Humidity and Temperature Sensors for Harsh Envi...

Author: S. Becker In many applications, humidity is not the actual problem—it is air quality....

Humidity and Temperature Sensors for Harsh Envi...

Author: S. Becker In many applications, humidity is not the actual problem—it is air quality. Che...

Hochfeuchte Sensorik für Pharma & temperaturgeführte Logistik

High-humidity sensors for the pharmaceutical in...

In this article, we’ve explained in detail why humidity measurement is essential under high-humidity conditions...

High-humidity sensors for the pharmaceutical in...

In this article, we’ve explained in detail why humidity measurement is essential under high-humid...

We also manufacture individually

Do you have special requirements? As a manufacturer with our own production facilities in Germany, we are always in a position to produce products outside the standard range.

Contact us

Secure payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • EPS
  • Google Pay
  • iDEAL Wero
  • Klarna
  • Maestro
  • Mastercard
  • MobilePay
  • PayPal
  • Przelewy24
  • Union Pay
  • Visa

Do you have a question? We are at your disposal:

+49 911 519 470

Mo. - Fr. 7.00am - 5.00pm CEST