Rymaskon® 1000 C Controller - 24V
  • Temperature [°C] [°F],
    relative humidity [% RH],
    carbon dioxide (CO2) [ppm]
  • Control: temperature, solar shading
  • Output: Modbus RTU, 0-10V, switching contacts
  • Input: 1x NTC10K, 1x digital
  • Power supply: 24 V AC / DC
  • Flush-mount installation
  • IP30
The room control devices of the Rymaskon series 1000 are designed for controlling (up to 2 HVAC zones) in residential, hotel and office rooms, and they individually control the heating, cooling and fan stages of the interior space. The controller variants can be operated as stand-alone devices using the integrated control functions PI, PWM or 2-/3-point control. The product family is distinguished by its elegant design, intuitive operation and the many combination options of the individual components.
The room control devices Rymaskon series 1000 C (controller) are used for controlling and regulating heating fan coil units and blower fan coil units (fan coil). Depending on the type variant, the devices are available with analogue outputs (0 -10 V) as well as with digital / relay outputs, for controlling heating valves, cooling valves, 6-way valves, staged dampers or EC dampers. The control is carried out via PI, PWM or 2-/3-point control. With the changeover function, 2- and 4-pipe systems can be operated.
The Modbus communication interface or W-Modbus enables any time changing and monitoring of the climate parameters on the controller via the BMS. In addition, the functions solar protection (roller shutters, blinds) or lighting (with dimming function) can be controlled via the bus. The optical indication is provided via a 2" TFT display, and operation is via capacitive keys (Touchkeys).

In addition to the integrated temperature and humidity sensor, optional sensors for CO2 and VOC are available. Furthermore, an input for a passive temperature sensor (NTC10K) is available, as well as an input for a potential-free contact. For example, a window contact or a condensation guard can be connected. This ensures that all options are available to climate the rooms flexibly and individually.
All device types are available in the timeless Iduna 3 enclosure (112 x 89.5 x 24 mm) in white or black. The wall mounting is performed on standard flush-mounting boxes.

Technical data

Type of function Controller
Measured values Temperature, relative humidity, CO2
Communication Modbus RTU
Power supply 24 V AC/DC (± 10 %)
Output 0-10V + switching output
Color White
Display Yes
Measured quantity in addition to °C + %RH + CO2
Communication/Interface Modbus (RTU cable),
Slave, address range 1 to 247, RS 485 interface, max. 32 devices,
9600 / 19200 / 38400 / 57500 baud, 8N1, even / odd parity, 1 / 2 stop bits

Blog posts

Humidity Sensors for Animal Husbandry and Agric...

In our previous post, we already explained the specific demands that high humidity and near-condensation...

Humidity Sensors for Animal Husbandry and Agric...

In our previous post, we already explained the specific demands that high humidity and near-conde...

Humidity Sensors for Swimming Pools and Spa Areas

In our previous article, we described the specific challenges that high humidity, condensation, and harsh...

Humidity Sensors for Swimming Pools and Spa Areas

In our previous article, we described the specific challenges that high humidity, condensation, a...

High-Humidity Sensors in Industry & Manufacturing

In our previous post, we described the challenges that high humidity, condensation, and harsh environmental...

High-Humidity Sensors in Industry & Manufacturing

In our previous post, we described the challenges that high humidity, condensation, and harsh env...

High-humidity sensors in the food industry and ...

High humidity places special demands on the sensors used in many applications. In our previous...

High-humidity sensors in the food industry and ...

High humidity places special demands on the sensors used in many applications. In our previous ar...

CuRA - Customized Register Assignment

Define Modbus registers flexibly, individually and project-specifically In building automation, it's not just precision that...

CuRA - Customized Register Assignment

Define Modbus registers flexibly, individually and project-specifically In building automation, i...

Der neue LS-Flex: Leckagen an Rohren schneller entdecken

The new LS-Flex: Detect leaks in pipes more qui...

Early detection of water leaks is now not just an option, but a necessity. With...

The new LS-Flex: Detect leaks in pipes more qui...

Early detection of water leaks is now not just an option, but a necessity. With the LS-Flex we of...

Hochfeuchte im Griff – mit diesen Spezialisten

High humidity under control – with these specia...

Perfect performance – our special solutions for extreme humidity Where other humidity sensors have long...

High humidity under control – with these specia...

Perfect performance – our special solutions for extreme humidity Where other humidity sensors hav...

Kanalfeuchtefühler im Blick: Präzise, zuverlässig, preiswert – bei jeder Messung

Duct humidity sensors in focus: Precise, reliab...

in measurement and control technology, precision and reliability are crucial - especially when it comes...

Duct humidity sensors in focus: Precise, reliab...

in measurement and control technology, precision and reliability are crucial - especially when it...

Kanalfühler im Fokus – So steigern Sie Energieeffizienz und Betriebssicherheit

Focus on duct sensors - how to increase energy ...

In modern HVAC systems, the precise detection of humidity and temperature in the ventilation duct...

Focus on duct sensors - how to increase energy ...

In modern HVAC systems, the precise detection of humidity and temperature in the ventilation duct...

Druck im System? So behalten Sie Temperatur & Feuchte im Griff!

Pressure in the system? How to keep temperature...

Made for extreme conditions - HYGRASGARD® humidity and temperature sensors - specially developed for use...

Pressure in the system? How to keep temperature...

Made for extreme conditions - HYGRASGARD® humidity and temperature sensors - specially developed ...

We also manufacture individually

Do you have special requirements? As a manufacturer with our own production facilities in Germany, we are always in a position to produce products outside the standard range.

Contact us

Secure payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • EPS
  • Google Pay
  • iDEAL Wero
  • Klarna
  • Maestro
  • Mastercard
  • MobilePay
  • PayPal
  • Przelewy24
  • Union Pay
  • Visa

Do you have a question? We are at your disposal:

+49 911 519 470

Mo. - Fr. 7.00am - 5.00pm CEST